7.4.5 The stages of burnup
WARNING: Generation of dangerous
gases!
Observe the position of the air regulator on the stove
insert in accordance with chapter „7.3 Adjustment of
control elements“!
WARNING: Danger of deflagration!
Do not completely close the air regulator during the
fire phase, incompletely combusted gases may form.
When opening the filling door, the sudden onset of
air can trigger a deflagration! During combustion,
smoke and flames may escape when the firebox
door is opened. Do not open the door until there are
no more flames!
CAUTION: Hot surfaces!
In heating mode, the stove insert heats up conside-
rably. Use the supplied heat protection glove for safe
operation.
iDetermine the exact position of the air regulator
during operation.
Stage 1: heating and heating phase
Completely open air regulator. This setting
allows the supply of the required, full combus-
tion air requirement. After lighting, leave this
setting until there are no more flaming (yellow)
flames!
Open
Stage 2: Performance phase
Move the air regulator to the middle position. As
a result, the air supply is throttled and the bur-
ning time is stretched. If a burning charcoal bed
has formed, additional firing material can be
added if necessary. If no further firing material
is refilled, it is possible to proceed to stage 3.
Stage 3: Ember phase
Air supply can therefore be throttled. In this
position of the air regulator is a rapid cooling of
the stove insert over the stove draft prevented.
Another heating process must now be re-ignited
beginning with stage 1.
Closed
14


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Camina-Schmid Neo Line 8563 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Camina-Schmid Neo Line 8563 in the language / languages: English as an attachment in your email.

The manual is 3.73 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Camina-Schmid Neo Line 8563

Camina-Schmid Neo Line 8563 User Manual - German - 32 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info