Installation
Logano GE615 - Subject to technical modifications.
20
B Push outer steam tube element with spring (L
3
)
first into the lower boiler hub.
B Hook the other outer steam tube elements (L
2
) onto
each other as shown in the detail drawing.
B Hook on the outer steam tube element with the handle
(L
1
) last.
B Close off lower boiler hub with flat gasket and dummy
flange.
Fig. 24 Inserting the outer steam tube
1 Outer steam tube element L
3
2 Outer steam tube element L
1
3 Gasket
4 Dummy flange
5 Outer steam tube element L
2
4.9 Boiler block pressure test (only
when supplied in loose sections)
A boiler block pressure test must be carried out (only
when supplied in loose sections). If supplied as a pre-
assembled block, the pressure test has already been
carried out in the factory.
For the further installation of a pre-assembled boiler block,
(Æ see Chapter 4.11.4, page 23).
4.9.1 Preparing for pressure test
B Close off flow and return connections (flow connection
flange with air vent valve).
B Slowly fill the boiler block with water via the fill and
drain connection. Vent the boiler block via the boiler
flow connection with air vent.
4.9.2 Perform pressure test
Carry out a pressure test with a test pressure of 8.6 bar
(in accordance with the requirements of the European
Pressure Vessel Directive).
Use a pressure gauge class 1.0 to measure the pressure.
B Drain water via fill and drain valve (Æ Fig. 23, [1],
page 19) upstream of the connection to the water
system, or if a hub joint is leaking.
4.9.3 Leaking hub joint
If you establish during the pressure test that hub joints are
leaking, follow the procedure described below.
The length and number of outer steam tube
elements depend on the boiler rating, and
can be worked out using the Æ Tab. 11
below.
Elements 9 10 11 12 13 14 15 16
L
1
480 mm1– 1– 1–
650 mm – 1 1 – 1 – 1 1
L
2
510 mm 1 1 – 2 2 – 3
680 mm – – 1 – – 2 2
L
3
450 mm 1
Tab. 11 Length and number of outer steam tube
elements
WARNING: Risk of accident as a result of
ignoring the safety regulations.
B Observe the relevant country-specific
standards, work safety legislation and
regulations for carrying out pressure tests.
NOTICE: Risk of system damage from
excessive pressure.
B The boiler block must not be connected to
the pipework of the heating system.
20


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Buderus Logano GE615 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Buderus Logano GE615 in the language / languages: English as an attachment in your email.

The manual is 3,05 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Buderus Logano GE615

Buderus Logano GE615 User Manual - German - 12 pages

Buderus Logano GE615 User Manual - Dutch - 12 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info