4.1 Assembling the Filter Head, Water Connection
!
Caution: Ensure that the locking handle on the head is open.
A
B
Close water intake and switch off power supply to the terminal equipment.
Fit the wall mounting bracket
5
in the intended position.
!
Caution: During assembly, note the installation dimensions, bending radii of the
hoses and dimensions of the accessories (e.g. BRITA FlowMeter). The system can be
operated vertically and horizontally. When using the wall mounting bracket, only install in
a vertical position!
C
Fit the hoses to water inlet “IN”
4
and outlet “OUT”
3
of the fi lter head
1
. With
G3/8" connections use fl at seals and with John Guest connections use hoses with an
8 mm diameter. Both safety clips
11
need to be used with John Guest connections after
assembling the hose.
!
Caution: The max. tightening torque at the G3/8" connections must not exceed
14 Nm! Only hose connections with fl at seals may be used because hoses with conical
screw connections may damage the fi lter head connections, thereby invalidating any
guarantee claims! Only hoses that comply with DVGW-W 543 may be used for connec-
tion to the device. The use of BRITA hose sets (Chapter 10) is recommended.
D
Check by-pass setting
10
and adjust to local carbonate hardness, if necessary
(Chapter 4.2).
Note: The by-pass has been factory set at 30%.
Lock the fi lter head
1
in the wall mounting bracket
5
.
4.2 Setting By-Pass and Capacity
Identify the carbonate hardness of the local water using the BRITA carbonate hardness test
(Art. 710800). Alternatively, your local water supplier will provide information on carbonate
hardness.
Note: The water is not decarbonised when using PURITY C AC fi lter cartridges; the carbonate
hardness does not need to be determined.
Determine the by-pass setting and capacity according to the application and the carbonate hard-
ness identifi ed using the by-pass and capacity table (Chapter 6).
Then turn the by-pass setting
10
to the identifi ed value.
Note: Only PURITY C 0–70% fi lter heads have a variable by-pass setting. Installation of the
BRITA FlowMeter 10–100 A (Art. 298900) is recommended for the precise, continuous control
of the degree of fi lter cartridge exhaustion.
Note: All the intake water is fi ltered when using PURITY C AC fi lter cartridges. The fi lter car-
tridge can be used with both a variable and fi xed by-pass. The by-pass used where required in
the fi lter head is not taken into account.
4.3 Inserting the fi lter cartridge
E
F
Remove protective cap
7
.
Note the next exchange date in the date fi eld on the fi lter cartridge
6
.
Insert the fi lter cartridge
6
vertically in the fi lter head
1
.
!
Caution: The fi lter cartridge can only be inserted when the locking handle is open.
Make sure that the fi lter cartridge is positioned correctly.
Turn the locking handle
2
until you feel it engage.
4.4 Commissioning
G
H
Open the water intake and switch on the terminal equipment’s power supply.
Operate the fl ush valve
8
and fl ush the fi lter system until the fi ltered water runs clear
and without bubbles. At least two empty fi lter cartridge volumes must be fl ushed
( Chapter 9).
Note: When bleeding/ ushing, catch water emerging from the fl ush hose
9
in an
appropriate container.
Check system for any leaks.
19


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Brita PURITY C at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Brita PURITY C in the language / languages: English, German, Dutch, Danish, French, Italian, Polish, Spanish as an attachment in your email.

The manual is 3,13 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info