16
Filter cartridge Flushing volume X
after 2–3 days stagnation
Flushing volume Y
after 4 weeks stagnation
PURITY C25 Quell ST 1.4 litres 14 litres
PURITY C50 Quell ST 2 litres 20 litres
PURITY C150 Quell ST 3 litres 30 litres
PURITY C300 Quell ST 6 litres 60 litres
PURITY C500 Quell ST 10 litres 100 litres
PURITY C1000 AC 1 litre 10 litres
The fi lter system must not be opened or dismantled during operation. The fi lter cartridge must
not be opened.
The fi lter head of the fi lter system has a service life of up to ten years (from the date of installa-
tion), provided that it is installed and used correctly and the operating conditions outlined in the
Technical Data chapter are adhered to. They must always be replaced after a maximum of ten
years. The hoses must be replaced in rotation after a maximum of fi ve years.
Production date
Production code – fi lter head – example: H 8252 11882
8 Production year, here: 2008
25 Production week, here: calendar week 25
2 Production day from Monday (1) to Friday (5); here: Tuesday
11882 Serial identifi cation number
Production code fi lter cartridge – example: B8252150010
8 Production year, here: 2008
25 Production week, here: calendar week 25
2 Production day from Monday(1) to Friday (2), here: Tuesday
15 Internal Identi cation No. of fi lter medium
0010 Consecutive number of the fi lter cartridge, here the tenth cartridge; reset the day changes
3.5 Technical Safety Assembly Instructions
The terminal device operated with the fi lter must be free of limescale prior to installation.
Protect the fi lter system from sunlight and mechanical damage. Do not assemble near sources
of heat and open fl ames.
A stop valve must be installed before the fi lter system inlet hose.
If the water pressure is greater than 8.6 bar, a pressure reducer must be installed in front of the
lter system.
No copper pipes and no galvanised or nickel-plated pipes/connectors may be installed between
the water fi lter and consumer. The use of BRITA hose sets is recommended here. When choos-
ing the material for parts that come into contact with water after the BRITA fi lter system it must
be remembered that, due to the process, the decarbonised water contains free carbon dioxide.
Note: The water is not decarbonised when using PURITY C AC fi lter cartridges.
All parts must be installed in accordance with the country-specifi c guidelines on the installation
of drinking water facilities (in Germany, for example, connection to the mains requires a DVGW-
approved non-return valve in accordance with DIN EN 13959 or higher quality protection against
return fl ows).
When installing and operating the fi lter system, the Employers’ Liability Insurance Associa-
tion regulations governing “Working in Commercial Kitchens” as stipulated by the Testing and
Certifi cation Body of the Expert Committee for the Food Processing Industry of the BG Central
Offi ce for Health and Safety at Work (BGR111) must be observed.
4 Installation
!
Caution: Prior to installation, read the technical data (Chapter 9) and the operating and safety
information (Chapter 3). After storage and transport below 0 °C, the product must be stored in the
open original packaging for at least 24 hours before it is commissioned at the stated ambient tem-
peratures (Chapter 9) for operation.
18


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Brita PURITY C at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Brita PURITY C in the language / languages: English, German, Dutch, Danish, French, Italian, Polish, Spanish as an attachment in your email.

The manual is 3,13 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info