19
8 Troubleshooting
8.1 No water fl ow
Cause: Water intake closed.
Troubleshooting: Open the water intake at the upstream stop valve or by closing the locking
handle
2
on the fi lter head
1
.
8.2 No or low water fl ow in spite of open water intake
Cause: Mains pressure too low.
Troubleshooting: Check mains pressure. If the fault persists, check the fi lter system and fi lter
cartridge and replace if necessary.
Cause: Filter head not mounted in direction of fl ow.
Troubleshooting: Dismantle lter head and install in direction of fl ow (Chapter 4).
8.3 Leak
Cause: Screwed connections not fi tted correctly.
Troubleshooting: Check mains pressure. Check all screwed connections and mount according to
Chapter 4. If the fault persists, replace fi lter system.
9 Technical Data
9.1 PURITY C Quell ST
PURITY C Filter System with Filter Cartridge
PURITY C25
Quell ST
PURITY C50
Quell ST
PURITY C150
Quell ST
PURITY C300
Quell ST
PURITY C500
Quell ST
Operating pressure 2 bar – max. 8,6 bar
Water intake temperature 4 °C to 30 °C
Ambient temperature
during
operation 4 °C to 40 °C
storage/transport –20 °C to 50 °C
Flow rate with 1 bar pressure loss 850 l/h 160 l/h 145 l/h 140 l/h 140 l/h
Nominal fl ow 30 l/h 60 l/h 60 l/h 60 l/h 100 l/h
Pressure loss at nominal fl ow 0.1 bar 0.25 bar 0.25 bar 0.25 bar 0.5 bar
Empty fi lter cartridge volume 0.85 l 1 l 1.9 l 2.9 l 5.4 l
Weight (dry/wet) 0.9 kg/1.2 kg 1.0 kg/1.4 kg 1.7 kg/2.5 kg 2.7 kg/3.9 kg 4.6 kg/7.1 kg
Comparable capacity according to DIN 18879-1:2007: The comparable capacity is a standardised measure to facilitate comparison
of various fi lters. The comparable capacity is determined under extreme conditions. The useful capacity in practical operation is
higher than the comparable capacity and may vary greatly depending on the usage conditions.
Comparable capacity 170 l 435 l 1278 l 2199 l 4125 l
Dimensions
(Width/Depth/
Height)
Filter system ( lter
head with fi lter
cartridge)
117 mm/
108 mm/
216 mm
117 mm/
108 mm/
267 mm
117 mm/
108 mm/
423 mm
124 mm/
123 mm/
477 mm
149 mm/
149 mm/
555 mm
Filter cartridge 108 mm/
108 mm/
208 mm
108 mm/
108 mm/
259 mm
108 mm/
108 mm/
415 mm
123 mm/
123 mm/
469 mm
149 mm/
149 mm/
545 mm
Installed dimensions
(vertical installation
with wall mounting
bracket)
137 mm/
130 mm/
216 mm
137 mm/
130 mm/
267 mm
137 mm/
130 mm/
423 mm
137 mm/
138 mm/
477 mm
149 mm/
151 mm/
555 mm
In addition to the accessories (e.g. FlowMeter), the bending radii of the intake and outlet hose must be considered in addition to
the dimensions of the complete system, depending on the installation orientation.
Operating position Horizontal or vertical
Water inlet connection G3/8" or John Guest 8 mm
Water outlet connection G3/8" or John Guest 8 mm
21


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Brita PURITY C at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Brita PURITY C in the language / languages: English, German, Dutch, Danish, French, Italian, Polish, Spanish as an attachment in your email.

The manual is 3,13 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info