- 7 -
Assembly
Alt/Az Positioning
The Alt/Az position of the telescope is ideal for quick observation of terrestrial and
astronomical objects. The telescope is swivelled in horizontal and vertical direction.
Alt/Az mounting of the telescope
1.Loosentheheightadjustment barclampingbolt (4,fig.15) andadjustthetiltplate
(2,fig.15)facingslightlyupwardssothatyoucaneasilyreachtheundersideofthe
plate. Now retighten the tilt plate height adjustment bar clamping screw so that the unit
cannotslipwhenthetelescopeismounted(seeFig.15).
2. Place the telescope on the tilt plate so that the side panel is to the left of the pole height
adjustment (1, fig. 17). Then place the other threaded hole over the other fixing screw
and hand-tighten both screws (see figure). 15).
3. Hold the telescope by the tilting plate and carefully loosen the tilt plate height adjustment
barscrew(4,fig.15)andlowerthetiltplateuntilitishorizontal(tilttheplatedownto
the stop, this is the horizontal position). Retighten the height adjustment bar screw to
lock the tilt plate in a horizontal position.
4. Release the altitude axis clutch on the telescopes fork arm and adjust the optical tube
ascloselyaspossibleto0degrees(horizontal)onthealtitudesettingcircleandthen
tighten the clamp again.
5. Release the azimuth axis clutch and slowly rotate the optical tube counterclockwise by
hand until it reaches the mechanical end stop.
6. Then slowly rotate the optical tube back again by hand until the telescope opening
points exactly north and tighten the clamp firmly again.
7. You have now reached the azimuthal start position. Now start an alignment method
(1-star, 2-star, etc.) to use the Goto function or move the telescope manually with the
direction keys.
Operation of an azimuthally mounted telescope
Your MCX is now azimuthally mounted on the field tripod (Fig. 17). The telescope can
be swivelled horizontally and vertically. When using the handheld computer (standard
equipmentontheMCX-102/127),theMCXcanbeusedinazimuthalmode.Thehandheld
computer then automatically tracks celestial objects simultaneously in horizontal and
vertical axes after a successful 1-star, 2-star, or 3-star alignment has been performed
(seep.24).Ifyousetupthetelescopeazimuthally,thedirectionofthetripodisarbitrary.
The legs of the field tripod can point in any direction. However, the tilting plate and the
tube must be horizontal. The tube opening must also face north (N, Fig. 17).
IMPORTANT NOTE!
To achieve a quick and precise horizontal alignment of the tripod, use the standard built-
in circular bubble (12, fig. 2) the telescope mount. The tripod is sufficiently levelled as
soon as the air bubble is within the circle mark.
Loosen the pole height clamping screw.
Fig.Fig. 16 16
Mounting the MCX on the tilting plate of the
tripod.
Azimuthal alignment: Tilt plate and tube are
horizontal. The tube opening faces north (N)
Fig. 15
e
c
Fig. 17
N
S
b
7


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Bresser 4701102 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Bresser 4701102 in the language / languages: English as an attachment in your email.

The manual is 3.85 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Bresser 4701102

Bresser 4701102 User Manual - German - 40 pages

Bresser 4701102 User Manual - Dutch - 40 pages

Bresser 4701102 User Manual - French - 40 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info