Rego 1000 – 6 721 831 662 (2021/03) en 13
6.4 Holiday
During holidays (absence), the heating can, for example, be kept at a
lower or higher level and hot water production can be switched off. Start
and Stop date, Room temperature and Block hot water production are
only displayed if the holiday function is activated.
3.1 Circuit 1 and hot water
3.1.1 Activate holiday function
3.1.2 Start date
3.1.3 Stop date
Set start and stop date for the desired period. Format yyyy-mm-dd.
The period starts and ends at 00:00. Both the start and end date are
included in the period.
Terminate the period prematurely by indicating No in menu item
3.1.1 Activate holiday function .
3.1.4 Room temperature
Set the room temperature that should apply to the circuit during the
period.
3.1.5 Copy to all heating circuits
3.1.6 Block hot water production
3.2 Circuit 2 (option)
Set the values in the same way as for 3.1 Circuit 1 and hot water .
3.3 Circuit 3 (option)
Set the values in the same way as for 3.1 Circuit 1 and hot water .
3.4 Circuit 4 (option)
Set the values in the same way as for 3.1 Circuit 1 and hot water .
6.5 Energy measurements
6.1 Generated energy
This displays 6.1 Generated energy in kWh divided into 6.1.1 Heating
and 6.1.3 Hot water.
6.2 Consumption electric additional heat
This displays 6.2 Consumption electric additional heat in kWh divided
into 6.2.1 Heating and 6.2.2 Hot water .
6.6 Timers
Timers are used by the control unit to count down the different time
dependent functions such as Extra hot water duration. At customer
level the following timers can be observed (only timers that are counting
are displayed):
6.7 External control
When an external input is connected, the control unit performs functions
which are set to Yes or is separated from 0 (Room temperature). When
the external input is no longer connected, the control unit returns to
normal mode. Only installed functions are displayed.
8.1 Heat pump 1
8.1.1 External input 1
8.1.1.9 Block compressor
8.1.1.11 Block additional heat
8.1.1.12 Block heating at tripped underfloor temperature limiter
8.1.1.13 Block heating
8.1.1.14 Room temperature
Set the room temperature that should apply in the event of enabled
external control.
Value > 0 °C enables the function.
The highest temperature is used if temperature changes have been set
for a certain circuit at several external inputs.
8.1.1.15 Block hot water production
8.1.2 External input 2
Set the values in the same way as for 8.1.1 External input 1 .
8.2 Heat pump 2
Set the values in the same way as for 8.1 Heat pump 1 .
8.5 External input circuit 2
8.5.2 Block heating at tripped underfloor temperature limiter
8.5.3 Block heating
8.5.6 Room temperature
8.6 External input circuit 3
Set the values in the same way as for 8.5 External input circuit 2 .
8.7 External input circuit 4
Set the values in the same way as for 8.5 External input circuit 2 .
6.8 General
Among other things, settings for date and time are available here.
12.1 Room sensor settings
12.1.1 Show outdoor temperature in room sensor
12.2 Set date
12.3 Set time
Check and change, if necessary, date and time. These are used by the
control unit to manage the different clock settings, e.g., holiday and
room temperature program.
12.4 Summer/winter time
Select if there should be automatic change over between summer
and winter time or not (dates according to EU standard).
12.6 Display contrast
If necessary, change the background light of the control panel.
12.7 Language
Change language, if desired.
6.9 Alarms
The different alarms that can occur are described in (Chapter 7).
Under 13 Alarms there is:
13.1 Information log
13.2 Delete information log
13.3 Alarm log
13.4 Delete alarm log
13.7 Alarm indication
13.1 Information log
Energy is measured per compressor; the calculated
results are added prior to being displayed.
Timer F value
7.1 Extra hot water 0h
7.3 Alarm mode delay 1h
7.5 Operating time for heating at hot water demand 20min
7.6 Hot water, operating time at heating demand 30min
7.7/7.8 Heat pump x timers
7.7.1/7.8.1 Compressor start delay 10min
7.11 Additional heat timers
7.11.1 Additional heat start delay 60min
7.11.2 Delay mixing valve control after additional heat start 20min
Table 8 Timers
13


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Bosch Rego 1000 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Bosch Rego 1000 in the language / languages: English as an attachment in your email.

The manual is 4.13 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info