1 609 92A 0KB | (25.4.14) Bosch Power Tools
measuring tool around the reference plane and measure dis-
tance “1” as for a length measurement.
Upon completion of the measurement,
the result for the sought distance “X” is
displayed in the result line c. The measur-
ing values for the distance “1” and the
angle “α” are displayed in the measured-
value lines a.
b) Double indirect height measurement (see figure D)
Press the function-mode button 4 until the indication for dou-
ble indirect height measurement appears on the display.
Measure distances “1” and “2” in this sequence as for a
length measurement.
Upon completion of the measurement,
the result for the sought distance “X” is
displayed in the result line c. The measur-
ing values for the distances “1”, “2” and
the angle “α” are displayed in the meas-
ured-value lines a.
Pay attention that the reference plane of the measurement
(e.g. the rear edge of the measuring tool) remains exactly at
the same location for all individual measurements within a
measuring sequence.
c) Indirect length measurement (see figure E)
Press the function-mode button 4 until the indication for indi-
rect length measurement appears on the display.
Pay attention that the measuring tool is positioned at the
same height as the sought measuring point. Now, tilt the
measuring tool around the reference plane and measure dis-
tance “1” as for a length measurement.
Upon completion of the measurement,
the result for the sought distance “X” is
displayed in the result line c. The measur-
ing values for the distance “1” and the an-
gle “α are displayed in the measured-val-
ue lines a.
Wall Surface Measurement (see figure F)
The wall surface measurement is used to determine the sum
of several individual surfaces with a common height.
In the example shown, the total surface of several walls that
have the same room height A, but different lengths B, are to
be determined.
For wall surface measurements, press the function-mode but-
ton 4 until the indicator for wall surface measurement ap-
pears on the display.
Measure the room height A as for a length measurement. The
measured value (
“cst”) is displayed in the top measured-val-
ue line a. The laser remains switched on.
Afterwards, measure length B
1
of the first
wall. The surface is automatically calcu-
lated and displayed in the result line c.
The length measurement value is dis-
played in the centre measured-value line
a. The laser remains switched on.
Now, measure length B
2
of the second
wall. The individually measured value dis-
played in the centre measured-value line
a is added to the length B
1
. The sum of
both lengths (“sum”, displayed in the
bottom measured-value line a) is multi-
plied with the stored height A. The total surface value is dis-
played in the result line c.
In this manner, you can measure any number of further
lengths B
X
, which are automatically added and multiplied with
height A.
The condition for a correct area/surface calculation is that the
first measured length (in the example the room height A) is
identical for all partial surfaces.
Grade Measurement (see figure G)
After pressing the grade measurement button 3, the indica-
tion for grade measurement appears on the display . The
backside of the measuring tool is used as the reference plane.
By pressing the grade measurement button 3 again, the side
surfaces of the measuring tool are used as reference plane
and the display view is shown turned by 90°.
Press the measuring button 2 to lock the measuring value and
accept it in the measured values memory. Pressing the meas-
uring button 2 again continues the measurement.
When the indication flashes during the measuring procedure,
then the measuring tool was tilted too much in lateral direc-
tion.
If the “digital vial” function is activated in the basic settings,
the grade value is also displayed in the other measuring func-
tions in line d of display 1.
Timer Function
The timer function is helpful, when, for example, movements
of the measuring tool during measuring are to be prevented.
To activate the timer function, press and hold button 6 until
the indicator appears in the display.
The time period from the actuation until the measurement
takes place is displayed in the measured-value line a. The time
period can be adjusted between 1 s and 60 s by pressing the
plus button 11 or the minus button 5.
The measurement takes place automati-
cally after the set time period has
elapsed.
The timer function can also be used for
distance measurements within other
measuring modes (e.g. area/surface
measurement). Adding and subtracting measuring results as
well as continuous measurements are not possible.
List of the last Measuring Values
The measuring tool stores the last 20 measuring values and
their calculations, and displays them in reverse order (last
measured value first).
1
2
1
OBJ_BUCH-1347-006.book Page 24 Friday, April 25, 2014 3:28 PM
24


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Bosch GLM 80 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Bosch GLM 80 in the language / languages: English, German, Dutch, Danish, French, Italian, Polish, Portuguese, Swedish, Turkish, Spanish, Norwegian, Finnish as an attachment in your email.

The manual is 8,79 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info