Bosch Power Tools 1 609 92A 1A3 | (1.6.15)
Noise/Vibration Information
Sound emission values determined according to
EN 60745-2-1.
Typically the A-weighted noise levels of the product are:
Sound pressure level 88 dB(A); Sound power level 99 dB(A).
Uncertainty K=3 dB.
Wear hearing protection!
Vibration total values a
h
(triax vector sum) and uncertainty K
determined according to EN 60745-2-1:
Drilling into concrete: a
h
=4.8m/s
2
, K=1.5 m/s
2
.
The vibration level given in this information sheet has been
measured in accordance with a standardised test given in
EN 60745 and may be used to compare one tool with anoth-
er. It may be used for a preliminary assessment of exposure.
The declared vibration emission level represents the main ap-
plications of the tool. However if the tool is used for different
applications, with different accessories or insertion tools or is
poorly maintained, the vibration emission may differ. This
may significantly increase the exposure level over the total
working period.
An estimation of the level of exposure to vibration should also
take into account the times when the tool is switched off or
when it is running but not actually doing the job. This may sig-
nificantly reduce the exposure level over the total working
period.
Identify additional safety measures to protect the operator
from the effects of vibration such as: maintain the tool and the
accessories, keep the hands warm, organisation of work pat-
terns.
Declaration of Conformity
We declare under our sole responsibility that the product de-
scribed under “Technical Data” is in conformity with all rele-
vant provisions of the directives 2011/65/EU, until
19 April 2016: 2004/108/EC, from 20 April 2016 on:
2014/30/EU, 2006/42/EC including their amendments and
complies with the following standards: EN 60745-1,
EN 60745-2-1.
Technical file (2006/42/EC) at:
Robert Bosch GmbH, PT/ETM9,
70764 Leinfelden-Echterdingen, GERMANY
Robert Bosch GmbH, Power Tools Division
70764 Leinfelden-Echterdingen, GERMANY
Leinfelden, 05.05.2015
Assembly
Before any work on the machine itself, pull the mains
plug.
Operation without Drill Stand
Use auxiliary handle(s), if supplied with the tool. Loss
of control can cause personal injury.
Always attach the auxiliary handle 12 when operating without
a drill stand. To do so, slide the auxiliary handle over the drill
spindle 15 onto the spindle collar (see illustration on the
graphics page). Tighten the wing bolt for adjustment of the
auxiliary handle 16 in clockwise direction.
The auxiliary handle 12 can be set to any position for a secure
and low-fatigue working posture.
Turn the wing bolt for adjustment of the auxiliary handle 16 in
anticlockwise direction and set the auxiliary handle 12 to the
required position. Then tighten the wing bolt 16 again in
clockwise direction.
Before any work, make sure that the wing bolt 16 is
firmly tightened. Loss of control can cause personal
injury.
Operation with Drill Stand
The safety and operating instructions for the drill stand
being used are to be strictly observed!
In order to make handling easier, you can clamp the power
tool in the drill stand for diamond drills GCR 180.
You must remove the auxiliary handle 12 before inserting the
power tool into the drill stand. To do so, loosen the wing bolt
for adjustment of the auxiliary handle 16 in anticlockwise di-
rection and slide the auxiliary handle down over the drill spin-
dle 15.
For mounting the power tool into the drill stand, please read
and observe the operating instructions of the drill stand.
Inserting/Replacing the Core Bit
Operation with drill stand: Before any work on the pow-
er tool, during work breaks and when not using the
power tool, secure the power tool against unintention-
al movement by tightening the locking brake. To do so,
read and follow the operating instructions of the drill
stand.
Core Bit Selection
Tool holder
11/4"UNC
Water supply pressure (max.)
bar 3
Weight according to
EPTA-Procedure 01:2014
without auxiliary handle
with auxiliary handle
kg
kg
5.2
5.5
Protection class /I
Diamond Drill GDB 180 WE
The values given are valid for a nominal voltage [U] of 230 V. For differ-
ent voltages and models for specific countries, these values can vary.
Henk Becker
Executive Vice President
Engineering
Helmut Heinzelmann
Head of Product Certification
PT/ETM9
Bosch core bits are colour-coded:
Wet-drilling core bits blue
Dry-drilling core bits light grey
OBJ_BUCH-2199-002.book Page 13 Monday, June 1, 2015 12:16 PM
13


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Bosch GDB 180 WE Professional at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Bosch GDB 180 WE Professional in the language / languages: English, German, Dutch, Danish, French, Italian, Polish, Portuguese, Swedish, Turkish, Spanish, Norwegian, Finnish as an attachment in your email.

The manual is 8,64 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info