For maintenance on behalf of the user, the vacuum cleaner
must be disassembled, cleaned and maintained as far as fea-
sible, without causing a risk for the maintenance personnel or
other persons. Prior to disassembly, the vacuum cleaner
should be cleaned in order to prevent any risks. The room/en-
closure in which the vacuum cleaner is disassembled should
be well ventilated. Wear personal protective equipment dur-
ing maintenance. After the maintenance, the maintenance ar-
ea should be cleaned.
Removing/Replacing the Flat-fold Filter
(see figures I1 – I2)
Replace a damaged flat-fold filter 24 immediately.
Pull the locking latch 16 and open the filter cover 34.
Grasp the flat-fold filter 24 by the fins, pull up and remove.
When taking out the flat-fold filter 24, remove any accumu-
lating dust and debris from the closing edge of the filter
cover 34 using a moist cloth.
PES and PTFE flat-fold filters can be flushed out under run-
ning water.
Insert a new or the cleaned flat-fold filter 24; observe prop-
er and tight seating.
Shut the filter cover 34 again (must be heard to engage).
Container
Wipe out the container 1 from time to time with a commercial-
ly available, non-scouring cleaning agent and allow to dry.
Level Sensors (see figure J)
Clean the level sensors 35 occasionally.
Unlock the latches 11 and remove the vacuum lid 10.
Clean the level sensors 35 with a soft cloth.
Reattach the vacuum lid 10 again and lock the latches 11.
Storage and Transport (see figure K)
Wind the mains cable around the cable holder 15.
Insert the accessories into the holders provided: Vacuum
tubes 29 in holders 17, crevice nozzle 25 in holder 18,
floor nozzle 28 in holder 19.
Undue the elastic tie-downs of the vacuum-hose holders 5
and place the vacuum hose 21 around the vacuum cleaner
lid into the holders 5.
Reattach the elastic tie-downs.
Mount the L-Boxx onto the retainers 9.
To prevent back injuries, remove a full disposal bag or dust
bag, or drain vacuumed-up fluids before transporting the
vacuum cleaner.
Carry the vacuum cleaner only by the carrying handle 8.
Store the vacuum cleaner in a dry room and secure it
against unauthorised use.
To lock the castors 14, actuate the castor brakes 13 by
pushing down.
Correction of Malfunctions
Problem Corrective Measure
The vacuum turbine does not start.
Check mains cable, mains plug, fuse, socket outlet and filling-level sensors
35.
Mode selector switch 6 set to “Start/Stop automatic”.
Set mode selector switch 6 to the “vacuum” symbol and switch the power
tool connected to the socket outlet 4 on.
Vacuum turbine switches off. Empty container 1.
Vacuum turbine does not restart after emptying
the container.
Switch vacuum cleaner off and wait 5 seconds; switch on again after
5 seconds.
Clean level indicators 35 as well as the space between the level indicators
35 with a brush.
Vacuuming power decreases. Remove clogs from vacuum nozzle, vacuum tubes 29, vacuum hose 21 or
flat-fold filter 24.
Replace disposal bag 23 or dust bag.
Engage filter cover 34 properly.
–Mount vacuum cleaner lid 10 properly and lock latches 11.
Replace flat-fold filter 24.
Dust escapes during vacuuming
Check proper installation of the flat-fold filter 24.
Replace flat-fold filter 24.
The automatic shut-off (wet vacuuming) does
not respond.
Clean level indicators 35 as well as the space between the level indicators
35 with a brush.
The automatic shut-off does not function with non-conductive liquids or
foam/bubbles.
Monitor the level continuously.
Automatic filter cleaning inoperative. Activate the filter cleaning (actuate the AFC button 3).
–Connect the vacuum hose 21.
OBJ_BUCH-1746-003.book Page 21 Wednesday, December 17, 2014 2:07 PM
21


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Bosch GAS 35 L AFC Professional at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Bosch GAS 35 L AFC Professional in the language / languages: English, German, Dutch, Danish, French, Italian, Polish, Portuguese, Swedish, Turkish, Spanish, Norwegian, Finnish as an attachment in your email.

The manual is 28,71 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info