1 609 92A 0XB | (17.12.14) Bosch Power Tools
Extraction of dusts resulting from running power tools
(see figure G)
An adequate ventilation rate (L) must be provided for
when the outgoing air is circulated. Observe the re-
spective national regulations.
A socket outlet with earthing contact 4 is integrated in the
vacuum cleaner. An external power tool can be connected
there. Observe the maximal allowable load of the connected
power tool.
Mount the tool sleeve 20 (see “Mounting the Tool Sleeve”,
page 19).
Insert the tool sleeve 20 into the vacuum connection of the
power tool.
To start the vacuum cleaner’s automatic
Start/Stop feature, set the mode selector
switch 6 to the “Automatic Start/Stop” sym-
bol.
–To start the operation of the vac, switch on the power tool
connected to the socket 4. The vacuum cleaner starts au-
tomatically.
Switch the power tool off to end the vacuuming.
The delayed action shutdown of the Automatic Start/Stop
continues to run for up to 15 seconds in order to extract re-
sidual dust from the vacuum hose.
To switch the vacuum cleaner off, set the mode
selector switch 6 to the “Off” symbol.
Wet Vacuuming
Do not vacuum inflammable or explosive fluids; for ex-
ample, benzene, oil, alcohol, solvents. Do not vacuum
hot or burning dust. Do not operate the machine in
rooms where the danger of an explosion exists. The
dusts, vapours or fluids can ignite or explode.
The vacuum cleaner may not be used as a water pump.
The vacuum cleaner is intended for vacuuming air and wa-
ter mixtures.
Before any work on the vacuum cleaner itself, pull the
mains plug.
Note: The requirements for the ingress degree (dust
category L) have only been proven for dry vacuuming.
Remove the disposal bag 23 or the dust bag and empty the
container 1 before wet vacuuming.
Note: For easier disposal when vacuuming liquid-solid mix-
tures, use a wet filter bag (accessory), which separates liq-
uids from solids.
Mount the rubber lips into the floor nozzle (see “Inserting
the Rubber Lip”, page 19).
Switch the automatic filter cleaning (AFC) off (see “Deacti-
vating the AFC”, page 20).
The vacuum cleaner is equipped with filling-level sensors 35.
When the maximum filling height is reached, the vacuum
cleaner switches off. Set the mode selector switch 6 to the
“off” symbol.
Note: When vacuuming non-conductive liquids (e. g. drilling
emulsion, oil and grease), the vacuum cleaner is not switched
off when the container is full. The level must be monitored
continuously and the container emptied in time.
To prevent the formation of mould after wet vacuuming:
Take out the flat-fold filter 24 and allow it to dry well.
Remove the vacuum cleaner lid 10 open the filter cover 34
and allow both components to dry thoroughly.
Filter Cleaning
Automatic filter cleaning (see figure H)
In automatic filter cleaning mode (AFC = Automatic Filter
Cleaning), the flat-fold filter 24 is cleaned every 15 seconds
by means of air blasts (pulsating noise).
The filter cleaning system must be actuated at the latest when
the vacuuming performance is no longer sufficient.
Regular use of the filter cleaning feature increases the tool life
of the filter.
To achieve ideal filter tool life, deactivate the automatic filter
cleaning in exceptional cases, e. g., when vacuuming pure liq-
uids or when working with a paper filter bag.
A flat-fold filter contaminated only on the surface is fully func-
tional. Manual cleaning of the flat-fold filter by striking/tap-
ping against it or blowing it out is not necessary, and can even
damage the filter.
Note: The automatic filter cleaning is factory-set.
Switching the automatic filter cleaning on/off is only possible,
when the VAC is running.
Deactivating the AFC
Actuate the AFC button 3.
The signalling LED 33 goes out.
Activating the AFC
Actuate the AFC button 3.
The signalling LED 33 lights up green.
Maintenance and Service
Maintenance and Cleaning
Before any work on the vacuum cleaner itself, pull the
mains plug.
For safe and proper working, always keep the vacuum
cleaner and ventilation slots clean.
Wear a dust protection mask when maintaining and
cleaning the vacuum cleaner.
If the replacement of the supply cord is necessary, this has to
be done by Bosch or an authorized Bosch service agent in or-
der to avoid a safety hazard.
A dust-technical inspection is to be carried out at least once
every year by the manufacturer or an instructed person, e. g.
for damage of the filter, tightness against leakage of the vacu-
um cleaner and function of the control/monitoring unit.
For category L vacuum cleaners that were in contaminated
environments, the exterior as well as all machine parts should
be cleaned or treated with sealants. When performing mainte-
nance and repair work, all contaminated components that
cannot be cleaned to satisfactory must be disposed of. Such
components must be disposed of in impermeable plastic bags
conforming with the valid regulations for the disposal of such
waste.
OBJ_BUCH-1746-003.book Page 20 Wednesday, December 17, 2014 2:07 PM
20


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Bosch GAS 35 L AFC Professional at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Bosch GAS 35 L AFC Professional in the language / languages: English, German, Dutch, Danish, French, Italian, Polish, Portuguese, Swedish, Turkish, Spanish, Norwegian, Finnish as an attachment in your email.

The manual is 28,71 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info