Maintenance and repair
23
5 Maintenance and repair
Properly maintained, your water heater will provide
years of dependable trouble-free, economic service.
It is suggested that a routine preventive maintenance
program be established and followed by the user
5.1 Periodic Inspection
It is further recommended that a periodic inspection of
the operating controls, heating elements and wiring
should be made by service personnel qualified in elec-
tric appliance repair.
Most electrical appliances, even when new, make some
sound when in operation. If the hissing or singing sound
level increases excessively, the electric heating element
may require cleaning. Contact a qualified installer or
plumber inspection.
5.2 Temperature and pressure relief
valve
At least once a year.
B lift and release the lever handle on the temperature
and pressure-relief valve, located on the back-right
side of the water heater to make certain the valve
operates freely.
Allow several gallons to flush through the discharge line
to an open drain.
5.3 Flushing tank
A water heater’s tank can act as a settling basin for sol-
ids suspended in the water. It is therefore not uncom-
mon for hard water deposits to accumulate in the
bottom of the tank.
To clean the tank of these deposits:
B Open the drain valve located near the bottom of the
unit and drain a few quarts of water from the water
heater once a year.
5.4 Draining the Water Heater
B Attach a garden hose to the drain valve located at the
bottom of the unit and direct that hose to a drain.
Warning: Internal components of the
heater can become extremely hot
during operation. Use caution when
servicing and removing the front and
rear covers.
Warning: Before manually operating
the relief valve, make certain no one will
be exposed to the danger of coming in
contact with the hot water released by
the valve. The water may be hot enough
to create a scald hazard. The water
should be released into a suitable drain
to prevent injury or property damage.
i
If the temperature and pressure-relief
valve on the hot water heater discharges
periodically, this may be due to thermal ex-
pansion in a closed water system. Contact
the water supplier or your plumbing con-
tractor on how to correct this. Do not plug
the relief valve outlet.
i
NOTE: If the power for the water heater is
turned off and then back on, the compres-
sor will not start for 3 minutes to avoid in-
ternal damage..
Danger: Before manually operating
the relief valve, make certain no one will
be exposed to the hot water released by
the valve. The water drained from the
tank may be hot enough to present a
scald hazard and should be directed to
a suitable drain to prevent injury or
damage.
Warning: If a relief valve discharges
water periodically, this may be due to
thermal expansion in a closed water
supply system. Contact your installer or
service provider for assistance. Do not
plug the relief valve.
Caution: Shut off power to the water
heater before draining water.
Danger: The water drained from the
tank may be hot enough to present a
scald hazard and should be directed to
a suitable drain to prevent injury or
damage.
23


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Bosch Compress 3000 - HP 200-1 E AI-F at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Bosch Compress 3000 - HP 200-1 E AI-F in the language / languages: English as an attachment in your email.

The manual is 1,37 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info