AMAX panel Settings | en 79
Bosch Security Systems B.V. Installation Manual 2019.08 | 11 | F.01U.309.277
Quick arming
This option enables/disables the quick arm function via which the user can arm the system by
pressing and holding [*] / [#] for three seconds without entering the code.
Installer access until next arming
Before using installer access, a standard user has to enable installer access first. If the option
installer access until next arming is enabled, installer access permission is limited to next
arming.
Force arm when system is in trouble condition
This option enables/disables the forced arming of an area although it is in a fault or tamper
condition.
Event record count per set/unset period
This option defines the maximum number of records for an event within the set / unset period.
Language version
In this option, the currently used language can be changed to the displayed languages.
Keypad 2 button alarm
This option enables/disables the keypad 2 button function:
The emergency alarm is transmitted, if [1] and [3], or [*] and [#] are pressed on the keypad
and held for three seconds. The fire alarm is transmitted, if [4] and [6] are pressed and held
for three seconds. The silent keypad emergency alarm is transmitted, if [7] and [9] are
pressed and held for three seconds.
System tamper indication
System tamper all areas
In case of a system tamper event, all keypads indicate an alarm. This option defines the
behavior of the alarm on the keypad for area 01 if the alarm is acknowledged on a master
keypad.
0 = area 1:
If the tamper event alarm is acknowledged on a master keypad and 0 = area 1 is selected,
the alarm on the keypad for area 01 is still indicated and has to be acknowledged
separately.
1 = all areas:
If the tamper event alarm is acknowledged on a master keypad and 1 = all areas is
selected, the alarm on the keypad for area 01 is not indicated any more.
Zone tamper bypass when DEOL zone is bypassed
If the option is enabled, the system creates a tamper alarm when DEOL zone is tampered,
even when this zone is bypassed or isolated.
Enclosure tamper timing
The AMAX panel supports different response times for the onboard tamper used for panel
enclosure. The response time value range is 000.0-999.9 seconds.
79


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Bosch AMAX panel 4000 EN at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Bosch AMAX panel 4000 EN in the language / languages: English as an attachment in your email.

The manual is 2,95 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Bosch AMAX panel 4000 EN

Bosch AMAX panel 4000 EN Quick start guide - German - 76 pages

Bosch AMAX panel 4000 EN Quick start guide - Dutch - 76 pages

Bosch AMAX panel 4000 EN Installation Guide - Dutch - 190 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info