Zone status report
This option defines whether and to which destinations a zone status report is sent.
The AMAX panel reports the zone status according to the specified path, including alarm, zone
fault, zone bypass and zone tamper alarm.
Unverified alarm report / cross zone
This option defines whether the unverified alarm report and cross zone options are allowed
for a zone. The following selections are possible:
Disable unverified alarm report and cross zone option
Allow unverified alarm report option
Allow cross zone option
Allow both unverified alarm report and cross zone option
Unverified alarm report
If the unverified alarm report option is allowed and when a cross zone is triggered, but no
alarm is created, system creates an unverified alarm in order to report. The system reports
unverified alarms if option unverified alarm report is enabled.
Cross zone
If the cross zone option is allowed, the process is as follows:
Prerequisites:
At least two zones in the same area have option cross zone enabled
System option cross zone timer is set to a value higher than 0
When one of these zones is triggered for more than 20 seconds, an alarm is created.
When one of these zones (the first zone) is triggered for a shorter time than 20 seconds, the
cross zone timer starts, no alarm is created at this time
When no more zones (with cross zone option) are triggered within the cross zone time,
no alarm is created
When the first zone is triggered twice or more within the cross zone time, no alarm is
created
When a second zone or further zones (with cross zone option) is / are triggered within
the cross zone time, then an alarm is created for all triggered zones
When the first zone or one of the other zones (with cross zone option) is / are triggered
twice or more after cross zone time is expired, the timer restarts
Zone domestic call
The system supports domestic call mode.
The process is as follows:
If the domestic call mode is configured for a zone and an alarm from this zone is created
the alarm will be reported via the onboard voice dialer to the destination(s) configured
and needs acknowledgement.
Zone alarm on keypad
This option enables / disables the zone alarm on the keypad. If this option is enabled, a zone
alarm can be sounded on the keypad buzzer.
If the keypad alarm tone function is disabled and the zone alarm on keypad function is
enabled, the alarm tone on the keypad is still enabled.
If the keypad alarm tone function is enabled and the zone alarm on keypad function is
disabled, the alarm tone on the keypad is still enabled.
71


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Bosch AMAX panel 4000 EN at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Bosch AMAX panel 4000 EN in the language / languages: English as an attachment in your email.

The manual is 2,95 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Bosch AMAX panel 4000 EN

Bosch AMAX panel 4000 EN Quick start guide - German - 76 pages

Bosch AMAX panel 4000 EN Quick start guide - Dutch - 76 pages

Bosch AMAX panel 4000 EN Installation Guide - Dutch - 190 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info