647499
45
Zoom out
Zoom in
Previous page
1/50
Next page
NL
FR
ES
EN
45
Repairs on electrical parts
Before calling the Technical Assistance Service
check that:
The plug has not come out of the socket.
The main switch in the home is on.
If necessary, have the appliance serviced by
qualified personnel.
Remove the plug from socket before disassem-
bling any part.
Replacement of feed cable
The feed cable must be in HO5 RR-F, with a
cross sectional area of 3x1 mm².
It can be replaced as follows:
open the terminal board;
connect the wires to their terminals:
N – L – Earth;
secure the wire with the cable clamp;
close the terminal board with screws;
N.B.: After installa-
tion the lead must be
accessible.
Fig. 5
Gas burner Gas Working Rate Nozzle Ø Rated Reduced
pressure 1/100 mm power power
Small auxiliary Liquid G30 30 mbar g/h 73 50 kW 1 kW 0,45
burner Liquid G31 37 mbar g/h 90 50 kW 1 kW 0,45
Liquid G30 50 mbar g/h 121 43 kW 1 kW 0,45
Liquid G31 50 mbar g/h 121 43 kW 1 kW 0,45
Natural G20 20 mbar l/h 94 71 kW 1 kW 0,45
Natural G25 25 mbar l/h 110 72 kW 1 kW 0,45
Medium semi Liquid G30 30 mbar g/h 127 65 kW 1,75 kW 0,45
fast burner Liquid G31 37 mbar g/h 157 65 kW 1,75 kW 0,45
Liquid G30 50 mbar g/h 212 58 kW 1,75 kW 0,45
Liquid G31 50 mbar g/h 212 58 kW 1,75 kW 0,45
Natural G20 20 mbar l/h 158 96 kW 1,75 kW 0,45
Natural G25 25 mbar l/h 165 94 kW 1,75 kW 0,45
Big fast burner Liquid G30 30 mbar g/h 218 85 kW 3 kW 0,85
Liquid G31 37 mbar g/h 269 85 kW 3 kW 0,85
Liquid G30 50 mbar g/h 363 75 kW 3 kW 0,85
Liquid G31 50 mbar g/h 363 75 kW 3 kW 0,85
Natural G20 20 mbar l/h 270 115 kW 3 kW 0,85
Natural G25 25 mbar l/h 292 121 kW 3 kW 0,85
Triple ring 3.3 kW Liquid G30 30 mbar g/h 240 93 kW 3,3 kW 1,40
Liquid G31 37 mbar g/h 296 93 kW 3,3 kW 1,40
Liquid G30 50 mbar g/h 400 73 kW 3,3 kW 1,40
Liquid G31 50 mbar g/h 400 73 kW 3,3 kW 1,40
Natural G20 20 mbar l/h 328 124 kW 3,3 kW 1,40
Natural G25 25 mbar l/h 323 130 kW 3,3 kW 1,40
Dual Liquid G30 30 mbar g/h 65 46 kW 0,9 kW 0,3
Liquid G31 37 mbar g/h 80 46 kW 0,9 kW 0,3
Liquid G30 50 mbar g/h 108 43 kW 0,9 kW 0,3
Liquid G31 50 mbar g/h 108 43 kW 0,9 kW 0,3
Natural G20 20 mbar l/h 85 72 kW 0,9 kW 0,3
Natural G25 25 mbar l/h 100 69 kW 0,9 kW 0,3
Liquid G30 30 mbar g/h 306 66 kW 4,2 kW 1,75
Liquid G31 37 mbar g/h 377 66 kW 4,2 kW 1,75
Liquid G30 50 mbar g/h 510 61 kW 4,2 kW 1,75
Liquid G31 50 mbar g/h 510 61 kW 4,2 kW 1,75
Natural G20 20 mbar l/h 400 102 kW 4,2 kW 1,75
Natural G25 25 mbar l/h 460 105 kW 4,2 kW 1,75
INT.
TOT.
Nozzle table
45


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Boretti BGR-116 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Boretti BGR-116 in the language / languages: English, Dutch, French, Spanish as an attachment in your email.

The manual is 3,55 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info