22
Installation
www.bora.com
The following switch contacts can be used:
Contact Function Connection
Home In Cooktop extractor on/off connection
for external switch contact (contact
closed: cooktop extractor on)
24V DC
100 mA
Home Out Electrically isolated contact for
controlling external devices depending
on the operating status of the cooktop
extractor (cooktop extractor on:
contact closed)
Maximum
250 VAC/
30 VDC,
2.5 A
Tab. 6.4 Switch contacts
INFO The Home In contact can be used for external
safety devices (e.g. window contact switches).
If the switch is open, the cooktop extractor is
out of operation.
Ensure that the control unit is disconnected from the
power supply.
Preparing the universal control unit
Remove the screws from the control unit.
Lift up the cover.
1
2
4
3
Fig. 6.29 Open the control unit’s cover
[1] Cover
[2] Electronic unit
[3] Base unit
[4] Switch contact clamp
INFO The electronic unit [2] can contain residual
charge. You must therefore be careful not to
touch the exposed contacts on the electronic
unit!
1
2
Fig. 6.28 Connection plug for the plinth fan
[1] Connection plug for the plinth fan control line
[2] Connection plug for the plinth fan power supply cable
Connect the plinth fan’s control line [1] to the control
unit [4].
Connect the plinth fan’s power supply cable [2] to the
control unit [6].
Release the power supply cable
To release the power supply cable [2] from the control
unit [6] you need a small flathead screwdriver.
Disconnect the control unit’s power supply cable from
the power supply [8].
Make sure that there is no power to the appliance.
Use the flathead screwdriver to loosen the lock on the
power supply cable’s plug.
To do this, insert the flathead screwdriver into the gap
in the socket.
Press the lock down gently.
Use the flathead screwdriver to gently lever the power
supply cable’s plug out of the control unit’s socket.
Now disconnect the power supply cable from the
socket.
Check the plug and the socket for damage.
Do not use damaged components.
Contact your BORA specialist supplier to replace any
damaged components.
Connecting an additional fan
Connect the fan’s control line [1] to the control unit
[5].
Connect the fan’s power supply cable [2] to the control
unit [7].
Check all the plug connections to ensure that they are
secure.
6.7 Connecting external switch
contacts
INFO The Home In and Home Out communication
connections must only be connected by a
certified specialist. The specialist also assumes
responsibility for the proper installation and
commissioning.
When using Home In and Home Out, you will require the
relevant documents for the external switching devices in
order to ensure safe device connection and operation.
22


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Bora CKASE at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Bora CKASE in the language / languages: English as an attachment in your email.

The manual is 6,61 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Bora CKASE

Bora CKASE User Manual - German - 32 pages

Bora CKASE User Manual - Dutch - 32 pages

Bora CKASE User Manual - French - 32 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info