Gas installation
www.bora.com
6.2.1 Additional installation notes for
Australia and New Zealand (AUS/NZS)
INFO Observe the requirements on the installation
of the appliance pursuant to AS/NZS 5601:
minimum clearance of the gas burner head from
flammable surfaces.
Please note all previous information in this section.
In addition, adhere to the requirements of the
currently applicable version of the regulations:
NZS5261/AS5601/AG601.
6.2.2 Gas connection AUS/NZS
Further technical requirements are considered:
AS/NZS 5263.1.1 2016 - Domestic Gas Cooking
Appliances.
Check the extended scope of delivery
Name Quantity
Gas regulator 1,00 kPa with test point for natural gas (NG)
1
Test point adapter for liquid gas (LPG) 1
Tab. 6.1 Extended scope of delivery for AUS/NSZ
Create the gas connection
The connection to a rigid and bend-resistant pipe must
be established as specified in AS/NZS 5601.
Pursuant to AS/NZS 1869 (AGA-certified and authorised)
and AS/NZS 5601, the connection to a safety hose
for gas must have a diameter of 10 mm, a class B or D
classification and a maximum length of 1200 mm.
Connect the appliance as follows:
Switch off the main switch/automatic circuit breaker
before connecting the cooktop.
Protect the main switch/automatic circuit breaker
from being switched on without permission.
Make sure the device is not energised.
Check the gas type and gas pressure of the gas supply
pipe.
Ensure that the appliance is equipped with the correct
nozzle type in order to guarantee a correct burner
flame and safe operation.
Connect the appliance as follows:
Set the control knob to the 0 position.
Close the gas supply.
Switch off the main switch/automatic circuit breaker
before connecting the cooktop.
Protect the main switch/automatic circuit breaker
from being switched on without permission.
Make sure the device is not energised.
Check the gas type and gas pressure of the gas supply
pipe.
Ensure that the appliance is equipped with the correct
nozzle type in order to guarantee a correct burner
flame and safe operation.
Remove the protective cap from the connection tube.
Use a security gas socket to connect this directly
to the connection bracket of the gas cooktop in a gas-
tight manner using a permitted security bracket.
If using a connection bracket, screw this on securely
with the attached seal.
ISO 228-1
ISO 7-1
(EN10226)
ISO 228-1
ISO 228-1
Tab. 6.2 Connection bracket
Only use the type of connection bracket permitted in
your country.
ISO 228-1/ISO7-1(EN10226): cylindrical/conical
ISO 228-1/ISO 228-1: cylindrical/cylindrical
Connect the appliance to the gas supply pipe.
Tighten all connections so that they are secure.
Check that installation has been done correctly.
Check the correct functioning of the stopcock.
Check the tightness of the gas connection by
conducting a leak test (see Leak test section).
Switch on the main switch/automatic circuit breaker.
Put the cooktop into operation (see the Operation
chapter).
Check all the functions and the burner flame are
working correctly.
20


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Bora CG11 Classic at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Bora CG11 Classic in the language / languages: English as an attachment in your email.

The manual is 2,05 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Bora CG11 Classic

Bora CG11 Classic User Manual - German - 32 pages

Bora CG11 Classic User Manual - Dutch - 32 pages

Bora CG11 Classic User Manual - French - 32 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info