Gas installation
www.bora.com
6 Gas installation
Observe all safety and warning information (see the
Safety section).
Observe all national and regional laws and regulations,
as well as the supplementary regulations of the local
gas supply companies.
Follow the enclosed manufacturer‘s information.
INFO Taking into account the applicable valid
regulations, the cooktop must be connected
to the gas line with an upstream stopcock.
INFO The gas supply pipe can be connected after
the gas cooktop has been installed.
INFO The hose connection must be laid in such a way
that it is not subject to deformation, buckling or
abrasion.
INFO The stopcock and gas supply pipe connections
must be accessible.
INFO It must be possible to inspect the entire length of
the hose line once installed.
INFO Only compatible connection pieces are to be used
for the hose line.
INFO
The gas connection hose line must not come into
contact with smoke or the flue outlet of an oven.
INFO The hose line must not come into contact with hot
surfaces on the cooktop or other devices.
The gas connection may only be carried out by an
authorised gas fitter in accordance with applicable legal
and local regulations. Comply with local regulations of the
utility companies.
Country Regulation/guidelines
Germany DVGW-TRGI 2008 or TRF 1996
Austria ÖVGW guideline G1
Switzerland SvgW Gas Regulations G1
EKAS guideline no. 1942:
Liquid gas, part 2
Regulations of the Vereinigung Kantonaler
Feuerversicherungen (VKF)
Netherlands,
Belgium,
France
Regulations of standard NBN D 51-003
Regulations and connection requirements
of the gas supply company (G.D.F.) and
electricity supply company (E.D.F)
Australia,
New Zealand
AS/ANZS5601 – gas installation
Tab. 6.1 Country requirements (information supplied without
liability)
6.1 Ventilation
This appliance is not connected to a flue gas evacuation
device. It must be positioned and connected in
accordance with the applicable installation conditions.
Suitable ventilation measures must be adhered to in
particular.
Always ensure sufficient ventilation during operation
(of the appliance).
6.2 Gas connection
This gas cooking appliance corresponds to device class 3.
It is equipped with a flexible connection tube.
When using a gas connection, the following
instructions are not to be followed in Australia or
New Zealand.
The installation of a security gas socket in the adjacent
enclosure is recommended.
The connection of liquid gas (LPG) is performed with
the interconnection of a sealed connection socket pipe
D: 8x1mm.
The connection to the gas supply is to be created with
flexible and seamless pipes made from stainless steel.
The connection with a security gas socket is to be
created in accordance with DIN 3383 with a maximum
length of 1500 mm.
The connection bracket and connection pieces must
be equipped with a 1/2 inch external thread in
accordance with the regulatory country requirements
(see table 6.2 Connection bracket).
19


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Bora CG11 Classic at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Bora CG11 Classic in the language / languages: English as an attachment in your email.

The manual is 2,05 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Bora CG11 Classic

Bora CG11 Classic User Manual - German - 32 pages

Bora CG11 Classic User Manual - Dutch - 32 pages

Bora CG11 Classic User Manual - French - 32 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info