577344
28
Zoom out
Zoom in
Previous page
1/202
Next page
03/ 2014
BENNING MM P3
20
8.5 Continuity test with buzzer
- Select the desired function (Ω, , ) by means of the rotary switch
7
of the
BENNING MM P3.
- Switch over to the continuity test ( ) by means of the „SELECT“ key
5
of the
BENNING MM P3 (press the key once).
- Bring the safety measuring leads into contact with the measuring points.
- If the resistance between the measuring points falls below 50 Ω, the integrated
buzzer of the BENNING MM P3 sounds.
See gure 6: Continuity test with buzzer
8.6 Capacity measurement
Before performing capacity measurements, discharge capacitors com-
pletely!
Never apply voltage to the capacity measurement jacks!
This might damage or destroy the device! A damaged device might
represent an electrical hazard!
- Select the desired function ( ) by means of the rotary switch
7
of the
BENNING MM P3.
- Determine the polarity of the capacitor and completely discharge the capacitor.
-
If necessary, make the null balance by means of the „RANGE/ REL Δ ( )“ key
6
.
- Bring the safety measuring leads into contact with the discharged capacitor ac-
cording to ist polarity and read the measured value on the digital display
of the
BENNING MM P3.
See gure 7: Capacity measurement
8.7 Frequency measurement
- In order to measure square wave signals of up to 5 V
SS
, select the desired func-
tion (Hz, %) by means of the rotary switch
7
.
- In order to measure sinusoidal signals of up to 600 V
eff
, select the desired func-
tion (V
AC
, Hz, %) by means of the rotary switch
7
and switch over to frequency
measurement (Hz) by means of the „SELECT“ key.
- Please observe the minimum sensitivity for frequency measurements of the
BENNING MM P3!
- Bring the safety measuring leads into contact with the measuring
points and read the measured value on the digital display
of the
BENNING MM P3.
See gure 8: Frequency/ pulse duty factor measurement
8.8 Pulse-Duty Factor Measurement
- Select the desired function (Hz, %) at the BENNING MM P3 by means of the
rotary switch
7
.
- Switch over to the pulse-duty factor measurement (%) by means of the „SELECT“
key
5
of the BENNING MM P3 (press the key once).
- Bring the safety measuring leads into contact with the measuring points and read
the measured value on the digital display
of the BENNING MM P3.
See gure 8: Frequency/ pulse duty factor measurement
28


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Benning MM P3 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Benning MM P3 in the language / languages: English, German, Dutch, Danish, French, Italian, Polish, Swedish, Turkish, Spanish, Norwegian as an attachment in your email.

The manual is 2,88 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.