577333
18
Zoom out
Zoom in
Previous page
1/120
Next page
09/ 2013
BENNING MM 4
12
which the current transducer is gripping is under an AC current of 0.1 A.
5.2.3 Sensor type: induction coil for alternating current.
5.2.4
Temperature coefficient of measurement value: 0.15 x (stated measure-
ment accuracy)/ °C with reference to the value at a temperature of 23 °C.
5.2.5 Max. apparent resistance at output: 120
5.2.6 Widest angle of tongs: 30 mm
5.2.7 Greatest conductor diameter 29 mm
5.2.8 Dimensions of current transducer (L x W x H) = 102 x 77 x 35 mm.
Weight of current transducer: 130 g
Note:
The current transducer can only be used for measurements when it is plugged
into the Multimeter.
6. Ambient conditions
- The BENNING MM 4 is designed only for measuring in dry surroundings,
- Maximum barometric height during measurement: 2000 m.
- Overvoltage category / set-up category: IEC 60664-1/ IEC 61010-1 →
300 V category III, 600 V category II,
- Degree of contamination: 2.
- Protection Class: IP 30 (DIN VDE 0470-1 IEC/ EN 60529)
IP 30 means: Protection against access to dangerous parts and protection
against solid impurities of a diameter > 2.5 mm, (3 - first index). No protec-
tion against water, (0 - second index).
- Operating temperature and relative humidity:
Multimeter
- At operating temperature of 0 °C to 50 °C: relative humidity under 80 %.
- current transducer:
At operating temperature of 0 °C to 45 °C: relative humidity under 75 %.
- Storage temperature:
The BENNING MM 4 can be stored at temperatures from -20 °C to + 60 °C.
The batteries must be removed from the unit.
7. Electrical data
Note: The measurement accuracy is stated as the sum of
- a relative proportion of the reading and
- a number of digits (i.e. numerical steps of the last place).
This measurement accuracy applies for a temperature of 23 °C and a relative
humidity under 75 %.
Sections 7.1 to 7.5 refer to the connection of the Multimeter to the circuit being
measured (current transducer removed). Section 7.6 refers to the combination
of Multimeter with current transducer in place.
7.1 DC voltage ranges
The input resistance is 9 MΩ
Measuring range Resolution Accuracy
Accuracy overload
protection
4.2 V 1 mV ± (0,5 % of reading + 2 digits)
600 V
eff
600
V
DC
42 V 10 mV ± (0,5 % of reading + 2 digits)
600 V
eff
600
V
DC
420 V 100 mV ± (0,5 % of reading + 2 digits)
600 V
eff
600
V
DC
600 V 1 V ± (0,5 % of reading + 2 digits)
600 V
eff
600
V
DC
7.2 AC voltage ranges
The input resistance is 9 MΩ parallel 100 pF. The reading is obtained by mean-
value rectification and indicated as effective value
Measuring range Resolution Accuracy
Accuracy overload
protection
4.2 V 1 mV
± (1.5 % of reading + 5 digits)
in frequency range 40 Hz - 300 Hz
600 V
eff
600
V
DC
42 V 10 mV
± (1.5 % of reading + 5 digits)
in frequency range 40 Hz - 500 Hz
600 V
eff
600
V
DC
420 V 100 mV
± (1.5 % of reading + 5 digits)
in frequency range 40 Hz - 500 Hz
600 V
eff
600
V
DC
600 V 1 V
± (1.5 % of reading + 5 digits)
in frequency range 40 Hz - 500 Hz
600 V
eff
600
V
DC
18


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Benning MM 4 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Benning MM 4 in the language / languages: English, German, Dutch, French, Italian, Polish, Swedish, Turkish, Spanish as an attachment in your email.

The manual is 6,87 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.