BENNING MM 1-1/ 1-2/ 1-3.
- Bring the safety measuring leads into contact with the measuring points. If the
lead resistance between the COM jack J and the jack for V, , , Hz 9 falls
below 25 , the integrated buzzer of the BENNING MM 1-1/ 1-2/ 1-3 sounds.
See gure 8: Continuity test with buzzer
8.6 Capacitymeasurement (BENNING MM 1-2/ 1-3)
Beforeperformingcapacitymeasurements,dischargecapaci
torscompletely!
Neverapplyvoltagetothecapacitymeasurementjacks!
Thismightdamage ordestroythedevice!A damageddevice
might represent an electrical hazard!
- Select the desired function ( ) by means of the rotary switch 8 of the
BENNING MM 1-2/ 1-3.
- Determine the polarity of the capacitor and completely discharge the ca-
pacitor.
- Connect the black safety measuring lead to the COM jack J of the
BENNING MM 1-2/ 1-3.
- Connect the red safety measuring lead to the jack for V, , , Hz 9 of the
BENNING MM 1-2/ 1-3.
- Bring the safety measuring leads into contact with the discharged capacitor
according to ist polarity and read the measured value on the digital display
of the BENNING MM 1-2/ 1-3.
See gure 9: Capacity measurement
8.7 Frequencymeasurement (BENNING MM 1-2/ 1-3)
- Select the desired function (Hz) by means of the rotary switch 8 of the
BENNING MM 1-2/ 1-3.
- Connect the black safety measuring lead to the COM jack J of the
BENNING MM 1-2/ 1-3.
- Connect the red safety measuring lead to the jack for V, , , Hz 9 of
the BENNING MM 1-2/ 1-3. Please observe the minimum sensitivity for fre-
quency measurements of the BENNING MM 1-2/ 1-3!
- Bring the safety measuring leads into contact with the measuring
points and read the measured value on the digital display of the
BENNING MM 1-2/ 1-3.
See gure 10: Frequency measurement
8.8 Temperature measurement (BENNING MM 1-3)
- Select the desired function (°C or °F) by means of the rotary switch 8 of the
BENNING MM 1-3.
- Connect the temperature measuring adapter and the temperature meas-
uring lead to the COM jack (-) J and to the jack for V, , , Hz (+) 9
observing correct polarity.
- Arrange the end of the temperature measuring lead in the vicinity of the heat
source to be monitored. Read the measured value on the digital display
of the BENNING MM 1-3.
See gure 11: Temperature measurement
8.9 Voltage indicator
The voltage indicator function is possible from each position of the rotary switch.
No measuring leads are required as voltage indicator (non-contact detection
of an alternating eld). The detector is located on the upper part of the device
behind the LED. By pressing the „VoltSensor“ key 5, the display indication dis-
appears (if the display is switched on). If a phase voltage is localized, this is
indicated by an acoustic signal and a red LED signal M. An indication is made in
earthed AC current networks only! The phase can be determined by means of a
single-pole measuring lead.
Practical hint:
Interruptions (cable breaks) in cables lying around openly such as e.g. cable
reels, fairy lights etc. can be traced from the feeding point (phase) to the point
of interruption.
Functional range: 230 V
See gure 12: Voltage indicator with buzzer
8.9.1 Phase test
- Connect the red safety measuring lead to the jack for V, , , Hz 9 of the
BENNING MM 1-1/ 1-2/ 1-3.
- Bring the safety measuring lead into contact with the measuring point of the
system part and press the „VoltSensor“ key 5.
- If the red LED lights and if there is an acoustic signal, the phase of an
earthed AC voltage is applied to this measuring point (system part).
09/ 2013
BENNING MM 1-1/ 1-2/ 1-3
28


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Benning MM 1.2 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Benning MM 1.2 in the language / languages: English, German, Dutch, Danish, French, Italian, Polish, Swedish, Turkish, Spanish as an attachment in your email.

The manual is 12,72 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info