577341
25
Zoom out
Zoom in
Previous page
1/169
Next page
16
7.3 DC current ranges (BENNING MM 1-2/ 1-3)
Overload protection:
- 10 A (600 V) fuse, quick-acting, 50 kA, at the 10 A input ( BENNING MM 1-2/ 1-3),
Measuring
range
Resolution Measuring accuracy Voltage drop
2 A 1 mA
± (1.0 % of the measured value + 3 digits)
max. 2 V
10 A
*5
10 mA
± (1.0 % of the measured value + 3 digits)
max. 2 V
7.4 AC current ranges (BENNING MM 1-2/ 1-3)
Overload protection:
- 10 A (600 V) fuse, quick-acting, 50 kA at the 10 A input (BENNING MM 1-2/ 1-3),
Measuring range Resolution
Measuring accuracy
*4
within the frequency
range 50 Hz - 500 Hz
Voltage drop
2 A 1 mA
± (1.5 % of the measured value + 5 digits) max. 2 V
10 A
*5
10 mA
± (1.5 % of the measured value + 5 digits) max. 2 V
The measured value is obtained by mean value rectication and is displayed
as r.m.s. value.
*4
The measuring accuracy is specied for a sinusoidal curve. In case of non-
sinusoidal curves, the accuracy of the displayed value decreases. Thus, an
additional error results for the following crest factors:
Crest factor from 1.4 to 3.0 additional error ± 1.5 %
Crest factor from 3.0 to 4.0 additional error ± 3 %
*5
The maximum permissible operating time is limited from current value ≥ 7 A.
measuring value max. measuring time min. pause time
10 A 4 min. 10 min.
9 A 5 min. 10 min.
8 A 7 min. 10 min.
7 A 10 min. 10 min.
7.5 Resistance measuring range
Overload protection for resistance measurements: 600 V
eff
Measuring
range
*6
Resolution Measuring accuracy
Max. open-circuit
voltage
200 0.1
± (0.7 % of the measured value + 3 digits)
1.3 V
2 kΩ 1
± (0.7 % of the measured value + 3 digits)
1.3 V
20 kΩ 10
± (0.7 % of the measured value + 3 digits)
1.3 V
200 kΩ 100
± (0.7 % of the measured value + 3 digits)
1.3 V
2 M 1 kΩ
± (1.0 % of the measured value + 3 digits)
1.3 V
20 M 10 kΩ
± (1.5 % of the measured value + 3 digits)
1.3 V
*6
For automatic range selection (AUTO), the change-over point might be al-
ready at a value of 1400!
7.6 Diodeandcontinuitytest
The stated measuring accuracy is applies to a range between 0.4 V and 0.8 V.
Overload protection for diode tests: 600 V
eff
The built-in buzzer sounds in the case of a resistance R less than 250 Ω up
to 850 Ω. For a resistance R higher than 850 Ω, the buzzer does not emit an
acoustic signal.
Measuring
range
Reso-
lution
Measuring accuracy
Max. measuring
current
Max. open-
circuit voltage
10 mV
± (1.5 % of the measured value + 5 digits)
1.5 mA 2.0 V
7.7 Capacityranges(BENNING MM 1-2/ 1-3)
Conditions: Discharge capacitors and apply them according to the specied
polarity.
Overload protection for capacity measurements: 600 V
eff
Measuring range Resolution Measuring accuracy
2 nF 1 pF
± (1.9 % of the measured value + 8 digits)
20 nF 10 pF
± (1.9 % of the measured value + 8 digits)
09/ 2013
BENNING MM 1-1/ 1-2/ 1-3
25


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Benning MM 1.2 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Benning MM 1.2 in the language / languages: English, German, Dutch, Danish, French, Italian, Polish, Swedish, Turkish, Spanish as an attachment in your email.

The manual is 12,72 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info