Display Symbols and Audible Symbols
Y
Dangerous voltage warning (also double beep tone). Indicates input
voltages higher than 30 V ac or 60 V dc.
B
Low-battery voltage
- Negative polarity indicator
Overload Condition
Input Overload (highest range in autoranging) is indicated by “OL or OL” and a
continuous tone. Remove test leads from the measurement setup as the input is beyond
the range of the meter.
Display Overload (input exceeds the selected range while range is locked) is also indicated
by “OL or -OL”. Select the next higher range until a value is displayed, or return to
autoranging. If overload still exists in the highest range, remove test leads from the
measurement setup as input is beyond the range of the meter.
Note: In both instances, overload indication is normal in the ohms and continuity ranges
(no sound) when the leads are not connected to anything or when the measured value is
higher than the selected resistance range.
Incorrect Input Warning
The meter displays a function error code “Err” when a test lead is placed in the A input
jack and the Selector switch is not set to a current or capacitance range. (If the meter is
connected to a voltage source with leads connected for current, very high current could
result). All current ranges are protected with a fast acting fuse.
Dangerous Voltage Warning
Displayed voltage warning and double-beep warning when input voltages are greater than
30 V ac/60 V dc, Y.
Audible Feedback
The meter emits a single beep when a parameter is changed, a “valid” front panel button
is pushed, or Auto Min Max values are updated. A double beep indicates a dangerous input
voltage (>30 V ac or 60 V dc).
The meter emits a continuous tone in the case of input overload, for continuity
measurement when resistance is <40 Ω, and for current measurements, when the A input is
used and the current
exceeds 2 A.
10


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Beha-Amprobe HD160C at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Beha-Amprobe HD160C in the language / languages: English, German, French, Italian, Swedish, Spanish as an attachment in your email.

The manual is 3,71 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info