Analog Bargraph
The 41 segment analog bargraph indicates the percentage of the range the displayed
measurement relates to. The zero segment is lit when the instrument is turned on. Each
segment after that equals 2.5 % of range. The 400 mA, 40 MΩ, and Capacitance ranges are
limited to 16 segments.
Example: a 500 mV input in the 1 V range (50 %) is represented by 21 segments (50).
400mA (of a theoretical 1000 mA range) = 16 segments (40 %).
Disable Beeper and Auto-Power Off
You can disable the beeper and Auto Power Off by pressing and holding the REL button
while turning the meter ON.
Measuring Procedures
Turn instrument on by turning function/range switch away from OFF and
selecting the parameter you want to measure.
This instrument is autoranging on all ranges. It automatically selects the range
that gives the best resolution for the measured value. A range can be locked
through menu selection (see Button Functions, later in this manual). You
can tell which range you are in by the position of the decimal point and the
measurement unit displayed.
When connecting or disconnecting test leads to a circuit, always turn off power
to device or circuit being tested and discharge all capacitors.
Strictly observe the max input limits.
Do not change functions while test leads are connected to circuit.
Measuring DC Voltage (See Figure 1)
1. Set the Function Switch to L.
2. If
RANGE is displayed, press the RANGE button to enable auto ranging.
3. Connect the test leads: Red to
Temp VΩHz, Black to COM
4. Connect the test leads to the circuit test points.
5. Read the display, and, if necessary, correct any overload (OL) conditions.
11


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Beha-Amprobe HD160C at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Beha-Amprobe HD160C in the language / languages: English, German, French, Italian, Swedish, Spanish as an attachment in your email.

The manual is 3,71 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info