11.2.13.2 InsertControl function test
TIP
Before the fireplace insert is reassembled, a function test should be carried out.
Make sure that all components are correctly assembled with one another
Plug the power supply into the socket
The controller now moves to the maximum positions of the motor (calibration run)
Wait about 10 minutes after plugging in the power supply and check in that time that the air regu-
lator disc has completely closed and opened
After the 10 minutes has finished the air regulator disc must be either completely opened or
closed (depending on the program set)
TIP
After a successful function test the fireplace insert can be completely reassembled.
Should the air regulator not have completely opened and closed after the 10 minutes has finished,
check the following:
Check whether the installation kit has been installed according to the drawing
Check whether the screw connections on the air regulator disc might have been excessively
tightened
Check if the Bowden cable is possibly caught or blocked by a foreign body
Undo the connection between Bowden cable and installation kit
Check whether the installation kit can be easily adjusted without the Bowden cable
Check the Bowden cable for contamination. If it is contaminated, clean the Bowden cable. DO
NOT LUBRICATE!
Run the function test once more without the control unit being connected to the installation kit.
When doing so check whether the shaft of the Bowden cable reaches a distance of 38 mm.
11.2.13.3 How the InsertControl automatic combustion control works
InsertControl reacts only to differences in the flue gas temperature that take pace within certain peri-
ods. This information is transmitted by the temperature sensor to the controls. Should the temperature
sensor be defective or display a fault, the controls will automatically go into fault mode with 60% shut-
ter opening and no longer changes this position.
Operation
The InsertControl software consists of the following 6 program phases.
Calibration
Standby
Ignition phase
Combustion phase (air regulator 60 % (Eco) or 80 % (Normal))
Stoking phase
Ember phase
97


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Austroflamm Fireplace inserts slied flat II - Kamineinsatz Schieb flach II at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Austroflamm Fireplace inserts slied flat II - Kamineinsatz Schieb flach II in the language / languages: English as an attachment in your email.

The manual is 14.06 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Austroflamm Fireplace inserts slied flat II - Kamineinsatz Schieb flach II

Austroflamm Fireplace inserts slied flat II - Kamineinsatz Schieb flach II User Manual - German - 124 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info