EN
Burner turned off.
Check, which alarm is displayed.
If the display is black and without text, check the thermal fuse of the boiler. If there is no error,
probably is just the burner´s thermal fuse turned off. To start again, turn the power supply into
the burner off, remove the cover and press the small button between the connections of the
fuse of overheating. The thermal fuse is placed directly in the fuel–inlet tube. After restart,
mount the cover back and turn on the energy supply. Thermal fuse of the burner is switched off
at the temperature of 93 °C.
Signal text on display Explanation Error code
at recording
ERROR: IGNITION FAILED 10
ERROR: FIRE LOST DURING COMBUSTION Extinction by heating, restart
failed
11
ERROR: FIRE SENSOR Faulty photocell, abnormal light 12
ERROR: CIRCUIT BOARD OVERHEATED Temperature under the cover is
too high
13
ERROR: TEMPERATURE SENSOR „TOO LOW“ Faulty thermal sensor of the
built–in operation thermostat
14
ERROR: TEMPERATURE SENSOR „TOO
HIGH“
Faulty thermal sensor of the
built–in operation thermostat
15
ERROR: OPTO–SWITCH Faulty circuit board 16
ERROR: FAN ALWAYS ON Ventilator rotates, when it is not
supposed to
18
ERROR: FAN STOP Ventilator is stopped, when it is
not supposed to be
19
ERROR: FAN SLOW Ventilator rotates too slowly 20
ERROR: IGNITION 1 First ignition trial failed 21
ERROR: STOCKER Pellet feeder is not connected to
the burner
22
ERROR: BURN–DOWN FAILED Photocell recognizes signal also
15 minutes after setting „Burn–
down“
23
ERROR: LIGHT LOST DURING BURNING Photocell does not recognize
fire, restart failed
24
ERROR: SCRAPER NOT OPERATING Fault in circuit board of scraper
or in grate gear
25
ERROR: SCRAPER JAMMED Grate moves too slowly 26
63


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for ATTACK DPX Combi Pellet at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of ATTACK DPX Combi Pellet in the language / languages: English as an attachment in your email.

The manual is 8.73 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info