12 POSSIBLE ERRORS AND SOLUTIONS
Error Cause Solution
The indicator light „mains“ does
not shine
No voltage in the mains
Plug is not properly connected to the
socket
Faulty mains switch
Damaged current inlet conductor
Chec
k
Check
Replace
Replace
The boiler does no
t
achieve the
required parameters
Lack of water in the system
Too high pump output
Boiler output is not adequate to the
heating system
Fuel of low quality
Heat up flap is not tight
Low chimney draught
High chimney draught
Long heating up or operation with the
heat up flap open
Deformation of the fan blades
Insufficiently cleaned boiler
Clogged air inlet into the combustion
chamber
Refill
Set the flow and switching
Matter of the project
Burn dry and chopped wood
Fix
New chimney, suitable connection
Install the restriction flap into the
flue connection
Close the heat up flap
Replace
Clean
Clean
Door are not tight Damaged glass fibre cord
Nozzle is being clogged
Low chimney draught
Replace, adjust the door hinges
Do not burn small wood pieces and
rind
Wrong chimney
Fan does not rotate or it is noisy If the non–returnable thermostat is
used, it is disconnected by overheating
Clogged radial impeller
Faulty capacitor
Faulty motor
Faulty contact in the socket of the cur-
rent inlet conductor from the motor
Press the button of the thermostat
Clean the fan
Replace
Replace
Check
62


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for ATTACK DPX Combi Pellet at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of ATTACK DPX Combi Pellet in the language / languages: English as an attachment in your email.

The manual is 8.73 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info