Operation Manual - GB
GB
www.atmos.cz
GB - 19
19. Laddomat 21
With its construction, Laddomat 21 replaces the tra-
ditional connection composed of individual parts.
It is composed of a cast-iron body, thermoregula-
tory valve, pump, non-return flap valve, ball valves
and thermometers. When the water temperature
reaches 78 °C, the thermoregulatory valve opens
the water supply from the storage tank. The con-
nection with Laddomat 21 is considerably easier
and therefore, we recommend it. A spare thermo-
cartridge of 72 ° C is supplied with the Laddomat
21 device. It is used for boilers over 32 kW.
OPERATION DATA
Max. operating pressure
0,25 MPa
Design pressure
0,25 MPa
Test over pressure
0,33 MPa
Hoghest operating temperature
100°C
WARNING - Laddomat 21 is designed only for boilers with output up to 75 kW (inclu-
sive). We recommend using it only with boilers with output up to 50 kW (inclusive).
20. Thermoregulatory valve
Thermoregulatory valve type ESBE, TV 60 °C is used with
solid fuel boilers. When the boiler water temperature reaches
+ 60 °C , the thermoregulatory valve opens and fluid from
the building heating circuit (2) enters the boiler circuit ( 3 →
1). Inlets 1 and 3 always remain open. This ensures that the
minimum temperature of the water returning to the boiler
is maintained. If need be, a thermoregulatory valve set to a
higher temperature (E.g. 72°C) may be used.
Recommended sizes of the thermoregulatory valve TV 60°C.
For boilers: D14P, D21P, D25P .......................................................DN25, DN32