This operation must be obligatorily carried out by a professionally qualified person. It should be carried out at least once
a year and includes several elements:
1. Cleaning of the rear evaporator with the aid of a thin brush and a nondirty and nonchlorinated water spray.
2. Revision of instructions and operating issues of the unit.
3. Revision of the safety mechanisms.
4. Dusting the circuit board.
5. Checking the earth connections.
6. Checking the gas pressure.
PREVENTIVE MAINTENANCE
A record should be kept of each element repaired or substituted as well as of all maintenance and repairs.
The surface of the exterior panels may be cleaned with a soft cloth and non-abrasive cleaner.
DISCONNECT THE EQUIPMENT FROM THE POWER SUPPLY before performing any maintenance procedures.
Take into account:
EVAPORATION UNIT:
The units should be kept clean and free of obstacles which may hinder the circulation of air through them. In
order to clean them, use water (no pressure) and non-abrasive detergents or cleaning liquids made specifically
for them (consult the manufacturer).
COMPRESSOR:
Compressor oil must be checked through the visor
Check that the resistance works correctly
Verify that the compressor refrigerates adequately with the circulating gas (verify the refrigerant charge).
Verify that the power consumption has not increased.
Verify that the compressor discharge pressure is not too high and that the intake pressure is not too low.
Verify that the compressor fasteners are not deteriorated.
Verify that no frost develops on the compressor.
CONDENSER:
Install the chemical dosers always alter the heating. under the pump level and as far as possible from it. Avoid
installing them in the inlet of the heat pump as condenser could be seriously damaged.
Do not set concentrated chemical products in the skimmers that could attack the Titanium include in the
condenser.
In cold areas where rarely froze, recirculating water it is enough to ensure good heating pump working
conditions if T is always over 0º C.
In cold weathers where froze is usual, it is necessary to purge all the cleaning and heating elements. In order to
do that, the condenser includes a plug to purge it.
FAN:
Verify the flows of the fan each year.
Clean the louvers of the fan as well as the protection grill regularly.
ELECTRICAL PANEL:
Verify all electrical connections.
Verify that there is no over-heating of the electrical terminals.
Verify that the protection systems operate correctly.
Verify that the regulator operates correctly and verify the temperature with a mercury thermometer (calibration
probe).
21


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Astralpool OPTIMA 15 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Astralpool OPTIMA 15 in the language / languages: English, Portuguese, Spanish as an attachment in your email.

The manual is 1,93 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info