The minimum size of the concrete fundament is depending on the moulded column’s height. For pillars
up to 2 m the fundament’s surface must be (60x60) cm at least. In case of pillars exceeding 2 m the
fundament surface must be at least (80x80) cm.
The fixing of the ground-plates on the concrete fundament is effected by means of 4 heavy-duty bolts
(providing moulded column heights up to 2 m, length 140 mm, M16) or via 2 concrete anchors (for pillars
exceeding 2, minimum depth 350 mm, dia. 16 mm).
3.3.2 Mounting of pillars
For the mounting of pillars on ground-plates the pillars need to be pre-drilled depending on the drillings on
the ground-plate. Please watch the specified maximum lengths of the pillars (max. length 1.5 m or 3.0
m, each depending on the ground-plate to be used).
For the mounting of pillars at walls, at the mounting side a distance of approx.
4 mm for the roof has to be considered. Provided that the pillars are to be mounted inside of buildings a
base-plate can be used instead of the roof which does not require any distance.
The roof and the base cover can be secured by a cover contact. For this purpose the cover contact must
be inserted either at the upper or lower end of the moulded column and then to be locked.
The transmitter and receiver are to be inserted in the pillars at the head and will be adjusted to desired
height through the screws at the upper and lower end of the housing. Before installation, please check
the cable laying inside of the pillars.
Devices and pillars which had already been pre-wired and checked in the laboratory
facilitate installation. Thus, only the earth cable needs to be connected on site.
8


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Aritech DO510 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Aritech DO510 in the language / languages: English as an attachment in your email.

The manual is 0,09 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info