TECHNICAL SPECIFICATIONS
Single unit Pillar mounted unit
Operating voltage 10-18 V AC or DC
Current consumption 55 mA per pair
Recommended range 100 m
Theoretical range 900 m
Measuring period ? 2 sec.
Alarm output Potential-free relay contact
Max. load 200 V DC, 0.5 A, max. switching power 10 W
Operating lag after alarm 5 sec.
Alarm response time 50-300 ms, adjustable at potentiometer
Armed/disarmed
input (receiver)
Electrical input, towards COM (reference conductor I/O)
Armed 0V-1.5 V/disarmed 3.5 V-Ub
First alarm memory
(receiver)
Open-collector towards COM max. load 12 V DC, 50 mA
Disqualification
(receiver)
Open-collector towards COM max. load 12 V DC, 50 mA
Sabotage contact Potential-free switching contact
max. load 100 V DC, 0.2 A
Infrared beam Wave length 940 nm
IR-impulse length 25 µs
Pulse pause relation 1:400
Keying ratio 2.5°
Alignment angle Horizontal ? 90°
Vertical ? 15°
Operating temperature -5 °C - +70 °C
-30 ° C - +70 ° C, with heating elements
Air humidity ? 98%
Housing
Dimensions LxHxD (203x96x95) mm LxHxD (169x96x75) mm
Protection class IP54 IP44, pillar
Weight 1400 g 650 g
Pillars
Pillar Pillar with 3 beam directions
Ground surface (130 x 123) mm
Length Each length, up to 6 m max.
Material Pillar made of anodised aluminium, black top and base cover made of aluminium die
cast
cover panes made of plexi-glass
Protection class IP44
Cover lock Potential-free connecting switch, max. load 100 V DC,
200mA, available as accessory upon request
Surmount protection Potential-free switch contact, max. load 100 V DC,
200mA, available as accessory upon request
17


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Aritech DO505 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Aritech DO505 in the language / languages: English, German, Dutch, French, Italian, Spanish as an attachment in your email.

The manual is 0,49 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info