This appliance was designed to be installed only inside buildings in compliance with the applicable norms in force.
Furthermore, installers are requested to keep to the following advice in the presence of:
- Damp: do not install the appliance in closed (unventilated) and damp rooms.
- Frost: do not install the appliance in areas where the temperature may drop critically and there may be a risk that
ice may form.
- Sunlight: do not expose the appliance to direct sunrays, even in the presence of windows.
- Dust/vapours/gas: do not install the appliance in the presence of particularly aggressive atmospheres such as acidic
vapours, dust or those saturated with gas.
- Electrical discharges: do not install the appliance directly on electrical supplies that arent protected against sudden
voltage jumps.
See warning no. 26
See warning no. 9 - In the case of walls made of bricks or perforated blocks, partition walls featuring limited
static, or masonry different in some way from those stated, you first need to carry out a preliminary static
check of the supporting system.
Install the appliance using the special bracket provided in the box, fastening it using 2 screws/Rawlplugs
measuring 6 mm in diameter.
See warning no. 10
Local norms could set forth restrictions regarding the installation in a bathroom environment. Therefore keep
to the minimum distances foreseen by the applicable norms in force.
The appliance should be installed as close as possible to the point of use to limit heat dispersion along the
piping.
See warning no. 20
Installing the appliance
Before making the plumbing connection, you must arrange for the system to be cleaned thoroughly to eliminate
any residue or dirt that could compromise the proper operation of the water heater.
Connect the water heater inlet and outlet to resistant pipes or pipefittings, as well as to the operating pressure, the
temperature of the hot water that could at times reach well over 80°C. We advise against the use of materials that
cannot withstand such high temperatures.
We recommend you use dielectric joints for the electrical insulation of the appliance from the water mains.
Connect the inlet pipe (marked with a blue rubber washer) and the outlet pipe (red rubber washer) to the corresponding
pipes of the system. Tighten couplings E using a pair of spanners as illustrated in fig. 4
In the event of low mains pressure values, install the appliance at no more than one metre above the tap (fig. 3) and
no more than 2 metres form the side of the latter.
Should these distances be greater than the recommended values, you must include an air valve on the hot water pipe.
Fill the appliance up and let the water flow out of the tap for a few seconds.
The water flow rate, with the tap turned on fully, should not be more than 5 l/min; for this reason, in accordance with
DIN 44531 norm, you should adjust the small valve (fig. 5) to limit the water flow.
In the presence of particularly hard waters, there will be a considerable and rapid formation of limescale inside the
appliance, with a consequent loss in efficiency and damage to the electric heating element.
Plumbing connection
Electrical connection
For greater safety, have qualified personnel carry out a careful inspection of the electrical system, ensuring it complies
with the applicable norms in force, because the appliance manufacturer will not be held responsible for any damage
caused by the lack of earthing of the system or for faults in the electricity supply.
See warning no. 24 - Check that the system is suitable for the maximum power absorbed by the water heater
(please refer to the data plate) and that the cross-section of the electrical connection cables is suitable, and
no less than 1.5 mm
2
.
The power supply cable (type H05 W-F 3x1.5, 8.5 mm in diameter) should be inserted in the corresponding hole (X
fig. 6) situated in the vicinity of the control knob and feed it until it reaches the thermostat slots (T fig. 6). The electrical
connection should be made directly on the terminals (D fig. 6) of the thermostat (respect the L-N polarity).
The appliance is fitted with a cable and plug. For installations without a plug, use a bipolar switch in conformity with
the applicable norms in force (fused with a minimum contact opening of 3 mm).
The appliance must be earthed and the earth wire (yellow-green colour) should be fastened to the special faston on
the heating element and marked with the (PE fig. 6). Secure the power supply cable in place using the special
cable clamp provided with the appliance
See warning no. 11
!
!
28


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Ariston Piccolo at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Ariston Piccolo in the language / languages: English, German, Dutch, French, Italian, Polish as an attachment in your email.

The manual is 1,12 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info