Heat pump water heater – INSTALLATION
38
4.10 Hydraulic connections
Connect the water heater inlet and outlet to pipes or pipe fittings that can withstand the operating pressure and
temperature of the hot water, which may reach 75 °C. It is not advisable to use materials that cannot withstand such
temperatures. The dielectric union fitting (supplied with the product) must be applied to the hot water outlet
pipe, prior to performing the connection.
Screw a “T” fitting identified by a blue collar onto the appliance’s water inlet pipe.
It is mandatory to fit a safety valve onto the appliance’s water inlet pipe. The device
must comply with the EN 1487:2002 standard and must have a maximum pressure of
0.7 Mpa (7 bar). Moreover, it must at least include the following components: a cut-
off valve, a non-return valve, a control mechanism for the non-return valve, a safety
valve and a water pressure shut-off device.
The device’s relief outlet must be connected to a relief pipe with a diameter no less than that of the appliance’s
connection (3/4”), with the aid of a siphon creating an air gap of at least 20 mm to allow for visual inspection; this is to
prevent any harm to persons and animals or damage to objects should the device activate and for which the
manufacturer shall not be held liable. Use a flexible pipe to connect the pressure safety device inlet to the cold water
system pipe, using a cut-off valve if necessary. Additionally, a water discharge pipe must be fitted to the outlet in case
the drainage tap is opened.
Avoid overtightening the pressure safety device and do not tamper with it. It is normal for water to trickle from the
pressure safety device during the heating phase; for this reason, it is necessary to connect the outlet, which must
always be left exposed to the atmosphere, to a drainage pipe that slopes downwards and towards an area not subject
to frost. It is advisable to also connect the condensate outlet to the same pipe, through the connection located on the
lower side of the water heater.
The appliance must not operate with water hardness levels below 12 °F; on the other hand, it is advisable to use a
suitably calibrated and monitored water softener in the event of particularly hard water (>25 °F); in this event, the
residual hardness must not fall below 15 °F.
If the mains pressure is close to the calibrated valve values, a pressure reducer must be installed as far as possible
from the appliance.
FIG 12. Caption: A:hot water outlet pipe / B: cold water inlet pipe / C: safety assembly / D: interception tap / E:
dielectric connection.
WARNING! It is advisable to carefully wash the system’s pipes in order to remove any residues of screw
thread, welding or dirt which may hamper the correct operation of the appliance.
4.11 Electrical connections
Description
Availability
Cable
Type
Protection
Alimentation cable not supplied 3G 1.5 mm
2
H05VV-F
16°
HC-HP connection cable not supplied 2G 0.5 mm
2
H05VV-F
External unit connection cable cable not supplied 5G 0.75÷1.5 mm
2
H05RN-F
Shielded probe connection cable between units cable supplied 4G
shielded – UL2464
WARNING: BEFORE YOU GET ACCESS TO TERMINALS, ALL SUPPLY CIRCUITS MUST BE DISCONNECTED
The batteries ensure that the product is protected against corrosion, when the appliance is not powered.
It is advisable to carry out a check on the electrical system to verify conformity to the regulations in force. Verify that
the electrical system can suitably withstand the water heater’s maximum power consumption values (refer to the data
plate), in terms of the size of the cables and their conformity to the regulations in force. It is forbidden to use multiple
outlet sockets, extension cables or adaptors. The earth connection of the appliance is required. It is forbidden to
use piping from the water, heating and gas systems for earthing the appliance.
Prior to operating the machine, make sure that the electricity mains voltage conforms to the value indicated on the
appliance’s data plate. The manufacturer of the appliance shall not be held liable for any damage caused by failure to
earth the system or due to anomalies in the electric power supply. To disconnect the appliance from the mains, use a
bipolar switch complying with all applicable IEC-EN regulations in force (minimum distance between contacts 3 mm,
switch preferably equipped with fuses).
The appliance must comply with the European and national standards, and must be protected by a 30 mA RCD.
38


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Ariston NUOS 200 SPLIT at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Ariston NUOS 200 SPLIT in the language / languages: English, Dutch, French, Italian as an attachment in your email.

The manual is 2,77 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info