MONOSPLIT INSTALLATION MULTISPLIT INSTALLATION
1L
2N
S
W
L
N
L
(A)
N
(A)
S
(A)
L
N
3. Fasten the cables using the cable clamp.
4. Put the cover back in place, ensuring it is positioned correctly.
3.3 Connecting to the mains electricity supply
Appliance connection must adhere to European and national standards, and must be protected by a 30 mA di erential
switch. Connection to the mains must be permanent (not using a plug) and equipped with an omnipolar switch com-
plying with current CEIEN standards (contact air gap of at least 3 mm when open, preferably tted with a fuse). Proper
connection to an e cient earthing system is essential for ensuring safe operation of the device.
1. Remove the cover.
2. Connect the conductors to the screw terminals. Screw the terminal board screws tightly to avoid any loosening.
3. Fasten the cables using the cable clamp.
4. Put the cover back in place, ensuring it is positioned correctly.
MONOSPLIT INSTALLATION MULTISPLIT INSTALLATION
1L
2N
S
W
L
N
L
(A)
N
(A)
S
(A)
L
N
3.4 Connection types
MONOSPLIT INSTALLATION
External unit model Power supply Switch type Connection cable
Connection
cable type
Power supply
cable
Power supply
cable type
NEVIS 25 MD0-O 220-240 ~ 50 Hz 20A 5G 1,5 mm
2
H07RN-F 3G 1,5 mm
2
H07RN-F
NEVIS 25 MD0-O 220-240 ~ 50 Hz 20A 5G 1,5 mm
2
H07RN-F 3G 1,5 mm
2
H07RN-F
NEVIS 35 MD0-O 220-240 ~ 50 Hz 20A 5G 1,5 mm
2
H07RN-F 3G 1,5 mm
2
H07RN-F
NEVIS 50 MD0-O 220-240 ~ 50 Hz 30A 5G 1,5 mm
2
H07RN-F 3G 2,5 mm
2
H07RN-F
MULTISPLIT INSTALLATION
External unit model Power supply Switch type Connection cable
Connection
cable type
Power supply
cable
Power supply
cable type
DUAL 55 XD0B-O 220-240 ~ 50 Hz 20A 4G 1,5 mm
2
H07RN-F 3G 1,5 mm
2
H07RN-F
TRIAL 80 XD0B-O 220-240 ~ 50 Hz 30A 4G 1,5 mm
2
H07RN-F 3G 1,5 mm
2
H07RN-F
QUADRI 110 XD0B-O
220-240 ~ 50 Hz 30A 4G 1,5 mm
2
H07RN-F 3G 2,5 mm
2
H07RN-F
PENTA 121 XC8B-O
220-240 ~ 50 Hz 30A 4G 1,5 mm
2
H07RN-F 3G 2,5 mm
2
H07RN-F
Power supply
Power
supply
48


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Ariston Nevis at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Ariston Nevis in the language / languages: English, Dutch, French, Italian, Portuguese, Spanish as an attachment in your email.

The manual is 5,69 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info