WARNING:
- Before carrying out any work, make sure that the units have been disconnected from the electricity supply.
- Make sure the systems to which the appliance should be connected comply with current applicable standards.
CHECKS WITHOUT THE USE OF TOOLS OR INSTRUMENTS
Operation in Cooling mode - Visual checks on the Internal Unit
Problem Check Action
1 - Frost forms on the Internal Unit heat
exchanger.
1.A - Frost only at the bottom of the heat
exchanger: gas leak.
1.B - Frost covers the entire heat ex-
changer: the air lter is clogged.
The room temperature is low
(< 20°C).
· Find the leak and recharge.
· Clean the air lter.
Unplug the appliance and switch o the
dedicated switch before cleaning (risk
of electrocution).
· Check the room temp.
2 - No condensation forms. 2.A - If the Internal Unit heat exchanger
remains dry and the electricity con-
sumption is much lower than the
rated value, then there is a leak.
· Find the leak.
· Replace the heat exchanger.
3 - The compressor runs but there is
little cooling.
3.A - The External Unit heat exchanger
is clogged or covered: you do not
have a good heat exchange.
3.B - The aps on the External Unit heat
exchanger are bent.
· Clean the External Unit heat exchanger.
· Straighten the aps on the external
heat exchanger.
4 - The air temperature is low, but there
is little cooling.
4.A - The Internal Unit lter is clogged.
4.B - The air recirculates in the Internal
Unit.
4.C - The machine has not been sized
correctly or is overloaded e.g.: heat
sources, overcrowding,...).
· Clean the lter.
· Encourage the free circulation of air.
· Replace the appliance or remove the
overload.
5 - The compressor does not start. 5.A - The compressor is very hot: heat
protection.
· Wait for the temperature to drop.
6 - The appliance comes to a stop after a
few minutes of operation.
6.A - The internal unit fan is broken. · Replace the motor.
· Only use original spare parts.
TROUBLESHOOTING - electrics
Problem Check Action
1 - The appliance gives no sign of life (no
LEDs lit, no beeps sounded), not even
when you press the ON-OFF button
on the internal unit.
1.A - Check whether there has been a
power failure.
1.B - Check whether the plug is inserted
fully in the socket in the wall.
1.C - Check whether the automatic switch
has blown.
1.D - Check whether the selector has
been set to stop.
· Restore the power supply and the cor-
rect connections.
· Plug the appliance in fully.
· Reset the automatic switch.
· Set the selector to another function.
2 - The remote control does not work or
only works from a short distance.
2.A - Check whether the batteries are
low.
2.B - Check whether there are any ob-
stacles (curtains or ornaments) be-
tween the remote control and the
air conditioning unit.
2.C - Check whether the distance be-
tween the remote control and the
unit is too far.
· Replace the batteries.
· Remove all obstacles.
· Move closer to the air conditioning unit.
50


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Ariston Nevis at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Ariston Nevis in the language / languages: English, Dutch, French, Italian, Portuguese, Spanish as an attachment in your email.

The manual is 5,69 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info