3. ELECTRICAL CONNECTIONS
WARNING:
Before performing any electrical connections, make sure that
the units have been disconnected from the electricity supply
and that the systems to which the equipment should be con-
nected conform to current standards.
- Only use cables with a suitable cross-section.
- Leave some extra length on the connection cables to allow for
future maintenance.
- Never connect the power supply cable by cutting it in half as
this could cause a blaze.
- If the power supply cable is damaged, it must be replaced by
the manufacturer or by its technical assistance service, or at
least by a suitably quali ed individual, in order to prevent all
hazards.
3.1 Connecting the internal unit
1. Slide the clip on the ap, remove the screws ( g. 1). Rotate and lock the panel by the clips. Open connections box( g.
2).
2. Route the internal/external unit connection cable behind the internal unit and prepare the end of the cable.
3. Connect the conductors to the screw terminals in accordance with the numbering.
MONOSPLIT INSTALLATION MULTISPLIT INSTALLATION
1L 2N
S
W
1L 2N
S
W
4. Use the wire clamp situated underneath the electrical terminal board.
5. Put the cover back in place, ensuring it is positioned correctly.
NOTE: the connection cables must not be routed near junction boxes, wireless data transmission systems (wi routers)
or other cables.
3.2 Connecting the external unit
1. Remove the cover.
2. Connect the wires to the screw terminals using the same numbering system as for the internal unit. Screw the ter-
minal board screws tightly to avoid any loosening.
NOTE:
Strip both ends of the wires in the power supply cable and the inter-
nal - external unit connection cable, as indicated in the gure, and
use the longest earth wire out of the active wires.
Make sure the wires do not come into contact with the piping or
other metal parts.
Fig. 1
Fig. 2
47


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Ariston Nevis at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Ariston Nevis in the language / languages: English, Dutch, French, Italian, Portuguese, Spanish as an attachment in your email.

The manual is 5,69 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info