719961
42
Zoom out
Zoom in
Previous page
1/80
Next page
42 /
SETTINGS - ADJUSTMENT - PROBLEM IDENTIFICATION MENUS
menu
sub-menu
Parameter
Description value
default setting
2 4 BOILER PARAMETER - PART 2
2 4 3 Post-ventilation after heating request 0 = OFF
1 = ON
0
2 4 4 Time delay after heating temperature
increase
from 0 to 60
(minutes)
16 Activated only with thermostat
On/Off and heating control
activated
(parameter 421 - 521 - 621 = 01)
This parameter allows the time delay to be set before automatic increase of the ow
temperature calculated in increments of 4°C (max 12°C). If this parameter retains the
value 00, this function is not active.
2 4 5 Circulation pump MAX speed from 75 to 100
2 4 6 Circulation pump MIN speed from 40 to 100
2 4 7 Device indicator for heating circuit pressure 0 = temperature sensor only
1 = pressure switch at minimum
2 = pressure sensor
1 RESERVED FOR TECHNICAL
ASSISTANCE
Only if the PCB is changed
2 4 8 <Not Available>
2 4 9 External temperatura correction from -3 to +3 (°C) 0 Only active with external sensor
connected
2 5 DOMESTIC HOT WATER PARAMETER
2 5 0 COMFORT function
E-COMBI ONE
0 = deactivated
1 = timed
2 = always on
0 Timer = activated for 30 minutes
after domestic hot water draw-
off
The appliance allows the hot water heating comfort to be increased via the
“COMFORT” function.
This function keeps the secondary exchanger temperature stable when the boiler is
not in use. When the function is active, the display shows COMFORT
Note: this function can be activated and deactivated by pressing the COMFORT
button
2 5 1 Comfort Anti-cycling Time
E-COMBI ONE
from 0 to 120 (minutes) 0
2 5 2 Hot water ow delay
E-COMBI ONE
from 5 to 200 (0.5 to 20 secon-
ds)
5 Anti “water hammering”
2 5 3 Extinction of the burner in D. H. W.
E-COMBI ONE
0 = anti-scale (stop at > 67°C)
1 = + 4°C /setting
0
2 5 4 Post-circulation and post-ventilation after a
domestic hot water draw-off
0 = OFF
1 = ON
0
OFF = 3 minutes post-circulation and post-ventilation after domestic hot water draw-
off if the boiler temperature measured requires it.
ON = always on for 3 minutes post-circulation and post-ventilation after domestic
hot water draw-off.
2 5 5 Domestic hot water timer from 0 to 30 (minutes) 0
2 5 7 <Not Available>
2 5 8 <Not Available>
2 6 BOILER MANUAL SETTINGS Only to test components
2 6 0 Manual mode activation 0 = OFF
1 = ON
0
2 6 1 Boiler pump control 0 = OFF
1 = ON
0 Set parameter 260=1
2 6 2 Fan control 0 = OFF
1 = ON
0 Set parameter 260=1
2 6 3 3 way valve control 0 = Sanitary
1 = Heating
0 Set parameter 260=1
2 6 4 <Not Available>
2 7 TEST & UTILITIES
2 7 0 Test mode TEST+
= Max Heating power
TEST+ = Max DHW power
TEST+
= Minimum power.
activation can also be obtained
by pressing the Reset button
for 10 seconds. The function is
deactivated after 30 minutes or
by pressing Reset
42


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Ariston E-System One at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Ariston E-System One in the language / languages: English as an attachment in your email.

The manual is 11,88 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Ariston E-System One

Ariston E-System One User Manual - English - 12 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info