SETTINGS - ADJUSTMENT - PROBLEM IDENTIFICATION MENUS
menu
sub-menu
Parameter
Description value
default setting
SERVICE CODE
Press
the button “+”
to select code 234 and press ok. Turn the encoder to select MENU and press OK button
0 NETWORK
0 4 DISPLAY SETTING
0 4 0 Zone to be set by display 1 = 1 Zone
2 = 2 Zone
3 = 3 Zone
1
0 4 1 Backlight timing
from 0 to 10 (minutes) or 24
(hour)
24
0 4 2 Thermoregulation button deactivation 0 = OFF
1 = ON
0
2 BOILER PARAMETER SETTING
2 0
GENERAL
2 0 0
DHW Setpoint Temperature from 36 to 60 (°C) Setting by DHW button 2
2 0 1
DHW Pre-heating 0 = OFF
1 = ON
RESERVED FOR TECHNICAL
ASSISTANCE
Only if the PCB is changed
2 1 BOILER PARAMETERS
2 0 0
Boiler circulator type (NOT ACTIVE)
2 2 BOILER GENERAL SETTINGS
2 2 0 Soft ignition from 0 to 90 60 See parag. Gas settings
2 2 3 Underoor thermostat or zone 2 ambient
thermostat selection
0 = Floor safety thermostat
1 = Zone 2 ambient thermostat
0
2 2 4 Thermoregulation 0 = Absent
1 = Present
0
2 2 5 Heating ignition delay 0 = Deactivated
1 = 10 seconds
2 = 90 seconds
3 = 210 seconds
0
2 2 8 Boiler Version - E-COMBI ONE
CANNOT BE MODIFIED
from 0 to 5 0
RESERVED FOR TECHNICAL
ASSISTANCE
Only if the PCB is changed
Boiler Version - E-SYSTEM ONE
CANNOT BE MODIFIED
from 0 to 5 2
2 2 9 Set boiler heat power
2 3 BOILER PARAMETER - PART 1
2 3 1 Maximum heating power setting from 0 to 99 60 see the “Gas setting” table,
information on Starting
2 3 2 Domestic hot water maximum percentage
CANNOT BE MODIFIED
from 0 to 99
RESERVED FOR TECHNICAL
ASSISTANCE
Only if the gas or PCB is
changed
see “gas setting” table
2 3 3 Minimum percentage
CANNOT BE MODIFIED
from 0 to 99
2 3 4 Heating maximum percentage
CANNOT BE MODIFIED
from 0 to 99
2 3 5 Selection of ignition delay type when
heating
0 = Manual
1 = Automatic
1
2 3 6 Ignition delay when heating timer setting from 0 to 7 (minutes) 3
2 3 7 Post-circulation when heating from 0 to 15 minutes or OC (AC) 3
2 3 8 <Not Available>
2 3 9 <Not Available>
41


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Ariston E-System One at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Ariston E-System One in the language / languages: English as an attachment in your email.

The manual is 11,88 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Ariston E-System One

Ariston E-System One User Manual - English - 12 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info