BOILER PROTECTION DEVICES
Anti-frost Device.
The anti-frost function acts on the central heating ow tempe-
rature probe, independently from other regulations, when the
electrical supply is turned on.
If the primary circuit temperature is between 3°C and 8°C the
pump will run (with the diverter valve switching between cen-
tral heating and hot water every 1 minute) until the temperature
reaches > 9°C.
If the ow temperature remains between 3°C and 8°C the pump
will continue to run for a maximum of 20 minutes unless a tem-
perature above > 9°C is detected in the central heating ow, af-
ter this the the burner will re (heating position) until a tempera-
ture of > 30°C is detected.
If the central heating ow temperature is < 3°C, the burner will
re (heating position) at minimum power until the temperature
reaches > 35°C, the burner will go out.
If lockout is caused by overheat the burner will not re but the
pump will continue to run (heating position).
The anti-frost device activates only when (with the boiler opera-
ting correctly):
- the system pressure is correct;
- the boiler is electrically powered;
- there is a supply of gas.
Ignition and Detecion
5 01
No ame detected
5 02
Flame detected with gas valve closed
5 04
Flame lift
5 P1
1st Ignition Failed
5 P2
2nd Ignition Failed
5 P3
Flame cut-off
Air Inlet / Flue gas outlet
6 10
Overheat (Main heat exchanger)
6 12
Insufcient fan speed
Multi-zone Heating (Heating Zone Modules - optional)
7 01
Zone 1 send sensor defective
7 02
Zone 2 send sensor defective
7 03
Zone 3 send sensor defective
7 11
Zone 1 return sensor defective
7 12
Zone 2 return sensor defective
7 13
Zone 3 return sensor defective
7 22
Zone 2 overheating
7 23
Zone 3 overheating
7 50
All Heating Zones locked
39


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Ariston E-System One at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Ariston E-System One in the language / languages: English as an attachment in your email.

The manual is 11,88 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Ariston E-System One

Ariston E-System One User Manual - English - 12 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info