719961
36
Zoom out
Zoom in
Previous page
1/80
Next page
36 /
COMMISSIONING
If the value measured corresponds to the value given in the
table, adjustment is complete, otherwise start the setting
procedure again.
Attention! If the value of the CO2 at the minum power has
been changed, it is necessary repet the adjusting at maximum
gas ow.
Operation 5 - Ending the adjustment
Exit cleaning mode by pressing RESET.
Stop the draw-off.
Verify and repair any leaks of gas.
Ret the front panel to the device.
Ret the blanking cover at combustion test point.
menu 2 - Boiler parameters
submenu 3 - parameter 1 Maximum Heating Power adjustment
submenu 2 - parameter 0
Soft light Ignition
submenu 3 - parameter 5 Heating ignition delay
Maximum Heating Power adjustment
The maximum heating power can be adjusted to between the
maximum power allowed by the boiler and the minimum power).
The display shows the value between 100% (“100” on the
display) and 0% (“0”) of this interval.
To check the maximum heating power, access menu 2/sub menu
3/parameter 1, check the value and, if necessary, modify it as
indicated in the Gas Regulation table below. (See page 40 for
more details).
Checking slow ignition power
The soft light can be adjusted between the maximum power
(shown on the display as “100”, i.e. 100%) and the minimum
power (shown on the display as “1”, i.e. 1%).
To check the slow ignition power, access menu 2/sub menu 2/
parameter 0.
Heating ignition delay adjustment
This parameter – menu 2/sub menu 3/parameter 5 - can be used
to manually (0) or automatically (1) set the delay time before the
subsequent reignition of the burner after it has switched off on
reaching the desired temperature in central heating mode.
By selecting manual, it is possible to set the delay in minutes
using the successive parameter (menu 2/sub menu 3/parameter
6), to a time between 0 and 7 minutes.
Automatic selection means that the boiler will establish the
delay time based on the set-point temperatureinstallation
instructions. Ensure the ue gas analyser used is calibrated and
set for the gas group the appliance is being adjusted for.
12. Check the appliance for gas leaks using gas leak detection
uid.
13. Afx the label to the appliance that is supplied with the
conversion kit.
27,4
21,4
3,4
3,9
E-COMBI ONE / E-SYSTEM ONE 30
E-COMBI ONE / E-SYSTEM ONE 24
Table summarising changes
(*) Gas diaphragm integrated in the air/gas mixer
(NON-REMOVABLE)
1 32 4
2
parameter
E-COMBI ONE
E-SYSTEM ONE
24 30
G20 G31 G20 G31
Lower Wobbe index (15°C, 1013 mbar) ( MJ/m
3
) 45,67 70,69 45,67 70,69
Inlet Gas pressure
20 30-37 20 30-37
Slow ignition 220
64 62
Maximum C. H.power Adjustable (%) 231
56 60
Minimum power (%) 233
3 3
Max CH power (%) 234
75 84
Max DHW power (%) 232
90 90
Gas diaphragm ((Ø) mm 5,0 (*) 3,6 5,8 (*) 4,0
Gas ow max/min
(15°C, 1013 mbar)
(nat - m3/h) GPL - kg/h)
max D.H.W 2,751 2,020 3,175 2,330
max C.H 2,328 1,709 2,963 2,175
min 0,391 0,287 0,455 0,334
36


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Ariston E-System One at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Ariston E-System One in the language / languages: English as an attachment in your email.

The manual is 11,88 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Ariston E-System One

Ariston E-System One User Manual - English - 12 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info