719964
39
Zoom out
Zoom in
Previous page
1/64
Next page
/ 39
SETTINGS - ADJUSTMENT - PROBLEM IDENTIFICATION MENUS
4 4 ZONE DEVICE MANAGEMENT
4 4 0 NOT PRESENT
5 ZONE 2 PARAMETER
5 0 ZONE 2 TEMPERATURE SETTING
5 0 0 NOT PRESENT
5 0 1 NOT PRESENT
5 0 2 NOT PRESENT
5 1 Entering access code 222 press the programming "+" button to
select 234 and press the meNu button
5 2 CYLINDER SETTING
5 2 0 Heating appliance temperature value setting 0 = from 20 to 45°C (low temperature)
1 = from 35 to 85°C (high
temperature)
1 select in the appliance type base
5 2 1 Basic heating control type selection type depending
on the peripheral devices connected
0 = fixed flow temperature
1 = device On/Off
2 = ambient sensor only
3 = external sensor only
4 = ambient sensor + external sensor
0 To activate heating control, press
the AUTO button. The Auto light is
illuminate
5 2 2 NOT PRESENT
5 2 3 NOT PRESENT
5 2 4 NOT PRESENT
5 2 5 Zone 2 heating maximum temperature setting 35 to + 82°C 82 if parameter 420 = 1
20 to + 45°C 45 if parameter 420 = 0
5 2 6 Zone 2 heating minimum temperature setting 35 to + 82°C 35 if parameter 420 = 1
20 to + 45°C 20 if parameter 420 = 0
5 3 DIAGNOSTICS
5 3 0 NOT PRESENT
5 3 1 NOT PRESENT
5 3 2 NOT PRESENT
5 3 3
Zone 2 set temperature
5 3 4
Zone 2 heat request
0=OFF
1=ON
5 3 5
Zone 2 Pump status
0=OFF
1=ON
5 4 ZONE DEVICE MANAGEMENT
5 4 0 NOT PRESENT
5 4 1 NOT PRESENT
5 4 2 NOT PRESENT
5 5 MULTIZONE
5 5 0 NOT PRESENT
5 5 1 NOT PRESENT
7 TEST & UTILITIES
7 0 0 Function test - Cleaning
turn the encoder to select the operating mode
t-- = funct. at Max heating power t-- activation can also be obtained by
pressing the Reset button for 10
seconds. The function is deactivated
after 10 minutes or by pressing Reset
7 0 1 Bleed cycle press Menu
8 PARAMETER FOR TECHNICAL ASSISTANCE
8 1 Entering access code 222 press the programming "+" button to
select 234 and press the meNu button
8 2 BOILER
8 2 0 NOT PRESENT
8 2 1 Fan status ON or OFF
8 2 2 Fan speed (x100) rpm
8 2 3 NOT PRESENT
8 2 4 NOT PRESENT
menu
sub-menu
Parameter
Description value
default setting
39


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Ariston Clas HE R at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Ariston Clas HE R in the language / languages: English as an attachment in your email.

The manual is 16,14 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info