719606
24
Zoom out
Zoom in
Previous page
1/270
Next page
EN
24
E50 – E51 – Maintenance request;
E60 – E90 – E91 – E92 – P.C.B. software error.
Reset: to reset the appliance, switch the product off and on again using the
button (Ref. A). If the cause of the mal-
function disappears immediately following the reset process, the appliance will resume normal operation. If this is not the
case,theerrorcodewillcontinuetoappearonthedisplay;contacttheTechnicalAssistanceCentre.
Activating the “thermal disinfection cycle” (anti-legionella)
The product has the "thermal disinfection cycle" disabled by default.
The activation of the "thermal disinfection cycle" is displayed as a normal temperature setting at 70°C.
For models featuring a user interface as represented in gures 3 and 4:
Activatethisfunctionbypressingandholdingboththe"ECO"and"+"keysfor4s.;onceactivationisconrmed,LED
70 will ash quickly for 4 s.
Permanently deactivate the function by repeating the above steps; once the deactivation is conrmed, LED 40 will ash
quickly for 4 s.
For models featuring a user interface as represented in gures 5 and 6:
Duringtheanti-bacteriacycle,thedisplayalternatesbetweenthetemperatureofthewaterandthetext“-Ab-”.
To disable/enable the function, while the product is in operation, press and hold the “mode” button for 3 seconds. Select
Ab0”(todisablethefunction)or“Ab1”(toenablethefunction)usingthe“set”knob,thenconrmbypressingtheknob.
Afterconrmingthatthefunctionhasbeendisabled/enabledsuccessfully,theproductwillreverttoitsnormaloperating
status.
Whentheproductisswitchedoff,theAnti-Legionnaire'sdiseasefunctionisnotactive.Intheeventthatthedeviceis
switchedoffduringtheAnti-Legionnaire'sdiseasecycle,theproductisswitchedoffandthefunctionisnotcompleted.At
the end of each cycle, the operating temperature returns to that set previously by the user.
Setting/adjusting the local time
(For models featuring a user interface as represented in gures 5 and 6)
To adjust the local time, the rst time the product is switched on it will automatically prompt you to set the correct time;
onsubsequentoccasionsyouwillneedtopressandholdthe"set"knobfor2seconds.Adjustthecurrenthoursetting
by turning the “set” knob, then conrm the value by pressing the knob. Repeat the procedure to set the minute value.
Adjusting the temperature and activating the functions
• For models featuring a user interface as represented in gures 3 and 4:
Press the
button (Ref. A) to switch on the appliance. Set the desired temperature by using the “+” and “-” buttons to
select a level between 40°C and 80°C. During the heating phase, the LEDs (Ref. 15) corresponding to the tempe-
rature reached by the water so far remain lit in a xed manner; all subsequent LEDs (up to the set temperature) ash
progressively.
If the temperature drops, for example after hot water has been used, the heating is reactivated automatically and the
LEDs between the last xed light and the light corresponding to the set temperature will resume ashing progressively.
The rst time the product is switched on, it will be set to a temperature of 70°C.
In the event of a power failure or if the product is switched off using the
button (Ref. A), the most recently set tempe-
rature remains memorised. During the heating phase, a slight noise may be produced as a result of the water heating
process.
• For models featuring a user interface as represented in gures 5 and 6:
Press the button (Ref. A) to switch on the appliance. The product has 4 operating modes: Manual, Programming 1,
Programming 2 and Programming 1and2. Every time the “mode button is pressed, a different operating mode will be
selected (the mode is indicated by the ashing of the corresponding LED near the display). Functions are selected on a
cyclic basis, in the following order: “P1”“P2” “P1andP2”“Manual” “P1”, etc.
Programmes “P1” and “P2” are set by default to the 07:00 and 19:00 time bands, and to a temperature of 70°C.
The “Manual function (“Manual” LED lit) allows the user to set the desired temperature simply by turning the “set” knob
until the selected temperature is displayed (the adjustment interval is 40°C - 80°C). If the knob is pressed, the setting will
be stored in the appliance memory and the product will begin operating in “Manual” mode.
ECO EVO: If the “Manual” function is used in conjunction with the “ECO EVO” function (see “ECO EVO function” para-
graph), the temperature will be set automatically by the product; this means the "set" knob will be disabled. If it is moved,
“ECO” will appear on the display for 3 seconds. If you wish to adjust the temperature, you will have to disable the “ECO
EVO” function.
The functions “Programming 1” (“P1” LED lit), Programming 2” (P2” LED lit) and Programming 1and2” (“P1andP2
LEDs lit) can be used to programme 1 or 2 time bands in the day during which hot water is required. Press the “mode”
button until the LEDs relating to the desired programme begin ashing.
Atthispoint,turnthe“set”knobtoselectthetimebandinwhichyouwouldlikehotwatertobeavailable(timebands
are selected in 30-minute notches). Press the knob to store the time band setting in the appliance memory. Next, set the
water temperature to the desired level (the adjustment interval is 40°C-80°C). Press the “set” knob to begin appliance
operation in “P1” or “P2” mode. If you have selected “P1andP2”, you will need to repeat the time band and temperature
setting procedures for the second time period. During the periods for which the use of hot water has not been scheduled,
24


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Ariston Blu Eco Evo at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Ariston Blu Eco Evo in the language / languages: English, German, Dutch, French, Italian, Polish, Portuguese, Spanish as an attachment in your email.

The manual is 8,39 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info