General
The acceptable voltage variation is: ± 10% during operation.
The electrical connection conduits must be fixed.
Class 1 unit.
Power supply and signal wires’ connection
To access the electrical panel, remove the front panel by removing the two screws on the bottom. When removing the
panel, be careful to disconnect the display board cable.
Emix must always be connected to the electrical power supply in a separate manner compared to the connection of the
outdoor unit, to which it is connected using only the bipolar shielded cable as all the other indoor units.
The power supply must come from an isolation and electric protection device (not supplied) in accordance with existing
regulations.
The installation must be protected by a double-pole circuit-breaker (not included).
Connect the communication bipolar shielded cable between Emix
and outdoor unit to the connection blocks C1 and C2 (terminal base
J12) and the shield to the communication ground connection; take
care about polarity between outdoor unit and Emix; In case of mis-
take you will see a communication error indication (all the LED ash-
ing). SEE AUTO-DIAGNOSIS TABLE.
Connect the single-phase 230 V 50 Hz to terminals L / N and the
earth wire to the terminal/s on the metal structure indicated by the
symbol of the earth connection.
ELECTRICAL CONNECTIONS
POWER SUPPLY
AC 230V
1 PHASE 50Hz
DELAYED FUSE
Main switch for disconnection from the supply
line must have a contact separation in all poles
that provides full disconnection under category III
overvoltage conditions.
ELECTRICAL WIRING DIAGRAM WITH THE OUTDOOR UNIT
TO OUTDOOR UNIT
FRONT VIEW BOTTOM VIEW
SCREWS
13


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Argo Emix at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Argo Emix in the language / languages: English, German, French, Italian, Portuguese, Swedish, Spanish, Finnish as an attachment in your email.

The manual is 4,64 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Argo Emix

Argo Emix User Manual - English - 29 pages

Argo Emix User Manual - German - 29 pages

Argo Emix User Manual - French - 29 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info