BK 710
2.3 - FLUE CONNECTION
The flue should be at least 3m high and at least 125mm diameter (5”) at no point should there be any
negative or horizontal gradients in the flue pipe.
It is recommended that a minimum height of 600mm from the stove before any significant change of
direction of the flue.
2.4 - VENTILATION
Ventilation should be in accordance with national regulations in the UK purpose provided ventilation is not
normally required BS5871 part 1 and in IE IS813 (IE Only).
2.5 - GAS CONNECTION
The gas connection can be made by removing the glass frame assembly; remove all the fixing screws a
keep safe for future use. Once the frame has been removed, the 4 no. fixings, holding the burner in place
can be removed and access to the gas inlet elbow can be gained. Once the connection has been made and
soundness verified the burner can be replaced ensuring correct position and the 4no. fixings replaced.
2.6 - PLACEMENT OF THE CERAMIC LOGS
WARNING—DO NOT CHANGE THE FUEL BED LAYOUT, THE TYPE OR
NUMBER OF LOGS.
Page 7
Contents Of Log Kit -
ITEM 1 -
Mica
Fill
Continued ….
ECOBURN PLUS GAS — INSTALLATION & SERVICE
7


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Arada Ecoburn Plus Gas at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Arada Ecoburn Plus Gas in the language / languages: English as an attachment in your email.

The manual is 8.98 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info