BK 710 Page 5
ECOBURN PLUS GAS—INSTALLATION & SERVICE
1.2 - FLUE & CHIMNEY SUITABILITY
This appliance is designed for use with conventional brick built or lined chimneys, all flues must conform to the
following minimum dimensions :
Before commencing installation a flue or chimney should be inspected to ensure that all of the following
conditions are satisfied :
1. Check that the chimney / flue only serves one fireplace and is clear of any obstruction, any dampers or
register plates must be removed or securely locked in the open position.
2. Brick / stone built chimneys or any chimney or flue which has been used for an appliance burning fuel
other than gas must be thoroughly swept.
3. Any under floor air supply to the fireplace must be completely sealed off.
4. Ensure that the inside of the chimney / flue is in good condition along its length and check that there is
no leakage of the smoke through the structure of the chimney / flue during and after the smoke pellet
test.
5. Using a smoke pellet check there is an updraft in the chimney / flue and that the smoke can be see
coming from the terminal / pot outside.
There must be no leakage of smoke through the structure of the chimney during or after the smoke
pellet test and it is important to check the inside upstairs rooms adjacent to the chimney / flue.
Check the chimney pot / terminal and general condition or the brickwork and masonry. If the chimney /
flue is in poor condition or if there is no up-draught do not proceed with the installation, if there is a
history of down draught conditions with the chimney / flue, again do not proceed until the fault has been
fixed.
A tested and certificated flue terminal or cowl suitable for the relevant flue type should be considered.
6. A spillage test must always be carried out during commissioning of this appliance.
Minimum dimension of flues 125 mm diameter.
Minimum effective height of all flue types 3 metres.
5


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Arada Ecoburn Plus Gas at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Arada Ecoburn Plus Gas in the language / languages: English as an attachment in your email.

The manual is 8.98 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info