Page 6 BK 710
WARNING
This stove is fitted with a spillage monitoring system consisting of a thermal switch, which shuts the appliance
off in the event of a blocked flue or inadequate flue pull occurring.
The system shall not be adjusted by the installer or shall not be put out of action.
When the spillage monitoring system is required to be replaced, only original manufacturers parts shall be
used.
If the stove switches off for no apparent reason, the appliance should not be used until expert advice is
obtained and the fault rectified.
All surfaces, except the control valve, are working surfaces and become very hot in use. They must not be
touched or any combustible materials put on them.
It is recommended that a fireguard complying to BS 8423 should be fitted for protection of young children or
elderly or infirm persons.
The door assembly has to be removed, to allow access to remove the glass frame assembly. Allow
this to cool before removing, as it will become very hot and is a working surface when the appliance is
in use.
SECTION 2 : INSTALLATION
2.1 - HEARTH
The stove must be installed on a non-combustible hearth with the hearth material being at least 12mm thick,
the hearth must protrude at least 150mm (6”) in front of the stove and be of a size sufficient to accommodate
the stove.
2.2 - SITING
The stove must not be installed in a bathroom.
Clearance from non-combustible material in the fireplace opening must be at least to dimensions in the table
below :
NOTE : Fitting the stove any closer to the back may cause nuisance shutdown of the stove as the air-
flow may be compromised and the thermal cut off will operate.
Position
Above
Back
Left
Right
Distance mm
100 mm
50 mm
100 mm
100 mm
300 mm
300 mm
300 mm
300 mm
Combustible Material Non Combustible Material
ECOBURN PLUS GAS — INSTALLATION & SERVICE
6


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Arada Ecoburn Plus Gas at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Arada Ecoburn Plus Gas in the language / languages: English as an attachment in your email.

The manual is 8.98 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info