ML5000 User Guide 35
I MAIN MIX MASTERS
Using the Engineers Wedge Monitor
It is best to use the same type of monitor speaker
as provided on stage. This lets the engineer hear
the sound as the performer hears it.
Select the WEDGE MODE switch I3 to configure
the C output as the engineers wedge monitor. Use
the insert to patch in any processing required, for
example a graphic EQ to preview changes in the
monitor before applying them to the mix being
checked.
Select LR, C, 2-TRK or none as the default monitor
source in section O . Pressing AFL overrides the
source to listen to a selected output. Pressing
PAFL overrides any AFL selection to check one or
more inputs. Releasing PAFL restores the
previously selected AFL. This is well suited to
monitor mixing where you need to listen to the
mixes in turn but quickly check individual inputs
along the way.
Pressing the TALK TO TB switch S6 automatically
dims the output by 20dB to prevent feedback
between the local speaker and talkback mic.
I1 MUTE. This momentary action switch turns the
master signal on or off. It can also be muted by the
mute groups, snapshot memories, solo-in-place and
MIDI note on/off messages. The switch illuminates
when the signal is muted.
The switch also functions as a solo select when the
console is in SIP mode, and as an edit key when in
EDIT GROUPS or EDIT SAFES mode. The mute
status is always displayed on the switch regardless
of operating mode.
I2 SAFE / EDIT. This green LED has a different
function according to console mode:
Normal The LED lights when the master has been
made safe from the snapshot and MIDI automation.
Solo-in-Place The LED lights when the master
has been made safe from solo-in-place.
Edit Safes Indicates that the master is safe from
the automation when entered from normal mode, or
safe from solo-in-place when entered from SIP
mode.
Edit Groups The LED lights to indicate that the
master is assigned to the selected mute group.
Preview Snapshots The LED lights to indicate
that the master is muted in the snapshot memory
being previewed.
I3 WEDGE MODE. This underpanel mode
switch configures the C output to become the
engineers monitor when the console is used for the
stage monitor application. When pressed the
monitor source is routed in mono through the C
insert and fader to the main output. The C mix
bypasses this section and is available from the
matrix outputs if needed. The switch is protected to
prevent accidental operation. Use a pen or pointed
implement to select the required mode.
I4 PEAK. The red PK LED senses the signal
both pre and post master fader and lights to warn
when the main mix is within 5dB of clipping.
Reduce the inputs to the mix if the LED flashes.
I5 FADER. The main mix L,R and C each have
a 100mm smooth travel K-fader providing +10dB
gain above the nominal 0dB operating position.
These faders are not part of the console VCA group
system.
PK
SAFE/EDIT
PK
SAFE/EDIT
PK
SAFE/EDIT
M
U
T
E
M
U
T
E
M
U
T
E
WEDGE
mode
MONITOR
C
OO
40
30
5
0
10
5
10
20
OO
40
30
5
0
10
5
10
20
OO
40
30
5
0
10
5
10
20
35


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Allen-Heath ML-5000 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Allen-Heath ML-5000 in the language / languages: English as an attachment in your email.

The manual is 3,46 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info