541356
18
Zoom out
Zoom in
Previous page
1/54
Next page
17
AUXILIARY SENDS - Route the channel signal to one or
more of 10 auxiliary send busses. These are independent
from the main outputs and may be used for effects sends
and monitor mixes. The sends are grouped 1-4, 5-8, and 9-
10. Each group may be selected pre or post channel fader.
A further 6dB of boost above 0dB normal channel level is
available on the send control.
Use post-fade for effects sends such as reverb. The amount
of signal sent to the effects unit follows the fader level and
mute switch. The processed ("wet") signal returned to the
mix through the return channel is therefore in proportion to
the direct ("dry") signal from the fader to the mix.
Use pre-fade for monitor sends such as to on-stage monitor,
backstage, orchestra pit, and musicians cue speakers. The
amount of signal in the monitor mix is independent of the
fader level. Pre-fade sends are post-EQ, post-mute as
standard. (may be configured pre-EQ or pre-mute by setting
internal links).
DIRECT OUT - The 0dBu post-fade channel signal is
available at the DIR OUT jack socket. For pre/post selection
and independent level control select the underpanel #
DIR OUT mode switch. The 9-10 pre/post switch and aux 10
send control now affect the direct out signal. Select POST
for an effects send dedicated to that channel (local effect)
without tying up a complete aux buss. Select PRE for a
multitrack recording send with independent level control.
MUTE - When illuminated the channel signal is turned off
(muted). This affects both pre and post fade signals unless
the pre-fade aux has been internally configured pre-mute.
The silent action mute element can be controlled by the
switch, mute groups, mute patches or via MIDI. The green
SAFE/PREVIEW LED indicates if the channel has been
made 'safe' so that it is not affected by the mute groups,
patches or MIDI. It is also used when previewing or editing
the groups and patches.
ROUTING and PAN - The PAN control positions the
channel signal in the stereo mix. The post-pan signal may
be routed directly to the L-R mix or to the groups in odd/even
pairs. The groups may be used to feed additional outputs or
recording tracks, or for subgrouping combinations of
channel signals to the mix so that the overall level of the
group can be controlled without affecting the balance between
the signals, for example the drum kit mics. The pre-pan
signal may be routed to the MONO output independent of the
stereo positioning.
METER and PFL - The peak reading meter displays the
channel signal pre-fader. Use this to monitor signal presence
and level. The signal should average around '0' with the
loudest peaking at '6'. If the red PEAK light flashes the signal
level is too high (5dB below clipping) and should be reduced
using the GAIN control to prevent possible overload distortion.
Press PFL to listen to the pre-fade signal on headphones or
engineers monitor without affecting the main outputs.
18


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Allen-Heath GL 4000 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Allen-Heath GL 4000 in the language / languages: English as an attachment in your email.

The manual is 2,51 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info