17. Circulation pump
Pump selection: Choice of pump.
*12 V pump, pump capacity is variably
adjustable with a potentiometer on the
back of the pump (1-5), normal mode
is 2, which works in most cases. Moun-
ted on the boiler.
*PWM controlled 12 V pump, this is a
variable speed controlled pump that
can be set to five dierent levels (1-5)
via the panel, normal level is 2, which
works in most cases. Mounted on the
boiler
*Extra 12 V pump, often located in the
expansion tank.
*230V pump. Often used in combina-
tion with an extra 12 V pump located in
the expansion tank.
If you have both a 230V pump and an
extra 12V pump installed, you will also
be able to select AUTO mode from the
menu.
Auto: In this mode the *230V pump is
on if 230V is connected. If 230V is dis-
connected, the additional 12V pump is
activated.
Pump setting: (Setting)
Cont.: The pump is in constant opera-
tion. (NB. This function limits the
supply of hot water, particularly when
there is a low heating requirement).
Therm: The pump is controlled by the
room sensor. This is the normal mode
for heat and hot water.
18. Automatic boiler start
Starting the boiler at a certain time
and day. The boiler will be on every
week during the time set, until the
function is deactivated. For automatic
start to function, the boiler must be
turned o.
19. Button sound
Turn the button sound on and o.
20. Reset
Press Reset and the panel returns to
factory setting.
NB. Settings made in installed fun-
ctions are deleted.
21. External start
The function is used when starting the
boiler from outside. When external
start has been activated the panel shall
be turned o. External start has three
modes, O, Ext and 230V. In the O
mode the function is turned o.
*Ext. The function is used when start-
ing the boiler through an external signal.
When the Ext. function has been acti-
vated, the control panel shall be turned
o, but 12V shall be connected. The
parameters/functions that the boiler shall
have when it starts shall be set before
turning o the control panel.
NB! Using this function requires installa-
tion of an accessory that can use external
start.
230 V. The function is used to start the
boiler when connection of 230V to
the vehicle takes place from outside.
When the 230V function has been
activated the control panel shall be
turned o but 12 V shall be connected.
The parameters/functions that the
boiler shall have when it starts shall be
set before turning o the control panel
(230 V connected). Certain vehicles
can be equipped with an individual
solution (*winter connection).
22. Language
Change between dierent languages
Available languages are English,
French and German.
However, the service menu is only
available in English (see section 8).
23. Installed functions
The accessories that are installed are
activated here (see section 11).
24. Service menu.
To exit the tools menu, press Return or
Menu.
Functions marked with a (*) are accessories, which are not installed on all vehicles, refer to the vehicle
manufacturer’s instructions.
10


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Alde Compact 3020 HE - rev1504 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Alde Compact 3020 HE - rev1504 in the language / languages: English as an attachment in your email.

The manual is 6,8 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Alde Compact 3020 HE - rev1504

Alde Compact 3020 HE - rev1504 User Manual - German - 18 pages

Alde Compact 3020 HE - rev1504 User Manual - Dutch - 18 pages

Alde Compact 3020 HE - rev1504 User Manual - French - 18 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info