Make sure that the device is protected from
rain and any direct exposure to water.
When attaching the suction and pressure
hoses, make sure that they do not exert a
tension on the device. We recommend the
use of flexible hoses at the pump inlet (13)
and outlet (3). If you have any questions,
ask your retailer.
When operating the system (automatic
operation), take appropriate measures to
ensure that damage due to flooding can-
not occur if the system should malfunction.
This can be ensured, for instance, by
installing an alarm system or a reserve
pump.
Attaching the suction hose
Choose a hose which is long enough so
that the device will not suck in air and run
dry. The hose should be at least 30cm
under the surface of the liquid to be
pumped while the pump is in operation.
Attach the suction hose. Make sure to screw
it in tightly, but take care not to damage the
threads.
If the liquid to be pumped is deeper than
4 m, you should use a suction hose which
is larger than 1“ in diameter for the best
performance. We recommend our AL-KO
suction set (14), which consists of a
suction hose, strainer and non-return
valve. The suction set is available at your
local retailer’s.
GB 3 Translation of original user instructions
When laying the suction hose, make sure
that it is lower than the system.
If the suction hose is laid so that it is higher
than the device, bubbles will be- come
trapped in the line and the pump will suck
air.
Attaching the pressure hose
Screw the connection nipple (17) with the
round seal ring (18) in the pump outlet (3).
Screw the angular nipple (15) with the flat
seal (16) on the connection nipple (17) and
rotate the angular nipple in the desired direc-
tion.
Attach the pressure hose. Make sure to
screw it in tightly, but take care not to dam-
age the threads.
Filling the pump
Before putting your domestic water sys-
tem into operation, you must fill the pump
chamber with water until it overflows to
achieve full suction power. Do not operate
the pump while it is dry because this will
cause serious damage to the pump.
Remove the filler screw (2).
Pour water into the opening until the cham-
ber of the pump (12) is full.
Replace the filler screw (2) and tighten it.
Switching on the system
Open the pressure line (open valve, sprayer,
tap, etc.).
Plug the electric cable into the socket. The
pump will automatically begin to run.
As soon as the flow of water is cleared of air
bubbles trapped in the line, close the pres-
sure line. When the pressure has fallen and
the reservoir is full, the pump will automati-
cally switch off. Your domestic water system
is now ready for operation.
Switching off the system
Switch the system off by unplugging the
electric cable from the socket.
Maintenance and Cleaning
!
Before beginning any maintenance or
cleaning work, make sure that the device
has been unplugged and take precautions
to ensure that it cannot be switched on
during work!
Cleaning the system
If you have used your domestic water system to
pump chlorine water (swimming pool water) or
liquids which leave a residue, flush your pump
out with clear water after use.
Cleaning the filter
Remove the screw plug (12) from the drain-
age opening, empty the filter chamber and
close the drainage opening again
Unscrew the filter cover (14) with the help of
the filter spanner.
Remove the filter (22) from the pump head
and clean it under flowing water.
11


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Al-ko HW F 1004 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Al-ko HW F 1004 in the language / languages: English, German, Dutch, Danish, French, Italian, Polish, Portuguese, Swedish, Turkish, Spanish, Finnish as an attachment in your email.

The manual is 3,77 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info